Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.
نویسندگان
چکیده
A 20-ml blood sample was collected from adult patients with suspected bloodstream infections and distributed equally into the four volume-controlled bottles of a blood culture set consisting of aerobic and anaerobic BACTEC Plus/F bottles and aerobic and anaerobic BacT/Alert FAN bottles. All bottles were incubated in their respective instruments for a standard 5-day protocol or until the instruments signalled positivity. Samples in all bottles with negative results by these instruments were terminally subcultured. A total of 8,390 blood culture sets were obtained during the study period, of which 4,402 (52.5%) met the study criteria. Of these, 946 (21.5%) were positive either by instrument signal or by additional terminal subculture of all negative bottles and yielded growth of microorganisms. Five hundred eighty-nine (13.4%) blood culture sets were considered to have recovered 663 clinically significant organisms. When both the BACTEC and the BacT/Alert systems were used, 465 positive sets were detected; BACTEC alone detected 52 positive sets and BacT/Alert alone detected 72 (P = 0.09). No differences were found between the two systems in microbial recovery rate from blood cultures obtained from patients on antibiotic therapy. Significantly more members of the family Enterobacteriaceae (P < 0.01) were detected from patients without antimicrobial therapy by BacT/Alert than by BACTEC. The false-negative rates were 0.20% for BACTEC and 0.32% for BacT/Alert. A significantly higher false-positive rate was found for BACTEC (P < 0.0001). Both systems were comparable for the time to detection of microorganisms. However, gram-positive bacteria were detected faster by BACTEC and Enterobacteriaceae were detected faster on average by BacT/Alert. We concluded that both systems are comparable in their abilities to recover aerobic and anaerobic organisms from blood cultures and a terminal subculture might not be necessary for either of the two systems. The increased positivity rate when using an anaerobic bottle in a two-bottle blood culture set is due to the additional blood volume rather than to the use of an anaerobic medium.
منابع مشابه
Controlled clinical comparison of VersaTREK and BacT/ALERT blood culture systems.
To assess the relative yields in automated microbial detection systems of bacteria and yeasts isolated from the blood of adult patients with suspected sepsis, we compared the new VersaTREK system (VTI) (TREK Diagnostic Systems, Cleveland, OH) to the BacT/ALERT 3D system (3D) (bioMérieux, Inc., Durham, NC). Identical protocols were followed for the two systems. Paired aerobic (REDOX 1) and anaer...
متن کاملA Critical Appraisal of the Role of the Clinical Microbiology Laboratory in the Diagnosis of Bloodstream Infections
The detection of bloodstream infections is one of the most important functions of clinical microbiology laboratories. Despite advances in blood culture technology and clinical studies that have focused on the detection of bacteremia and fungemia, perfection has not been achieved and uncertainties persist. This review provides perspectives on a number of areas, including the recommended number o...
متن کاملControlled evaluation of supplemented peptone and Bactec blood culture broths for the detection of bacteremia and fungemia.
Comparison of conventional blood culture media with newer formulations of Bactec media for radiometric detection are lacking. Therefore, we compared the yield and speed of detection of clinically important microorganisms with supplemented peptone broth (SPB) and Bactec aerobic (6B) and anaerobic (7C or 7D) broths in 7,627 blood samples from adult patients. Acridine orange stains from SPB, radio...
متن کاملComparative analysis of simulated candidemia using two different blood culture systems and the rapid identification of Candida albicans.
The goal of this study was to determine the time to detection of Candida species isolates using the two most commonly used automated blood culture systems, and to evaluate rapid, widely available methods for the presumptive identification of C. albicans. Candidemia models of eight commonly detected Candida species were prepared using ATCC standards. The times to detection were evaluated using t...
متن کاملAnalysis of 281,797 consecutive blood cultures performed over an eight-year period: trends in microorganisms isolated and the value of anaerobic culture of blood.
The results for 281,797 blood culture sets of specimens collected from adult patients at the Mayo Clinic over an approximately 8-year period (1 November 1984 through 30 November 1992) were analyzed in order to determine whether there were differences in the types of microorganisms isolated over this time and to assess the usefulness of anaerobic culturing of blood. Each blood culture set consis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 36 3 شماره
صفحات -
تاریخ انتشار 1998