The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system.

نویسندگان

  • H Mizu-uchi
  • S Matsuda
  • H Miura
  • K Okazaki
  • Y Akasaki
  • Y Iwamoto
چکیده

We compared the alignment of 39 total knee replacements implanted using the conventional alignment guide system with 37 implanted using a CT-based navigation system, performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs, lateral radiographs and CT scans. The mean hip-knee-ankle angle, coronal femoral component angle and coronal tibial component angle were 181.8 degrees (174.2 degrees to 188.3 degrees), 88.5 degrees (84.0 degrees to 91.8 degrees) and 89.7 degrees (86.3 degrees to 95.1 degrees), respectively for the conventional group and 180.8 degrees (178.2 degrees to 185.1 degrees), 89.3 degrees (85.8 degrees to 92.0 degrees) and 89.9 degrees (88.0 degrees to 93.0 degrees), respectively for the navigated group. The mean sagittal femoral component angle was 85.5 degrees (80.6 degrees to 92.8 degrees) for the conventional group and 89.6 degrees (85.5 degrees to 94.0 degrees) for the navigated group. The mean rotational femoral and tibial component angles were -0.7 degrees (-8.8 degrees to 9.8 degrees) and -3.3 degrees (-16.8 degrees to 5.8 degrees) for the conventional group and -0.6 degrees (-3.5 degrees to 3.0 degrees) and 0.3 degrees (-5.3 degrees to 7.7 degrees) for the navigated group. The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with a CT-based navigation system, especially with respect to rotational alignment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study.

Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiologica...

متن کامل

Use of the Cusum technique for evaluation of a CT-based navigation system for total knee replacement.

Most of the early failures of total knee replacements are related to technical flaws. Conventional ancillary devices achieve good alignment in the frontal plane in only an average of 75% of total knee replacements. Computer-assisted surgery may improve the technical quality of implantation surgery. The aim of our study was to evaluate the use of computer-assisted surgery using a quality control...

متن کامل

Implementation of a CT-based navigation system in two-stage reimplantation for infected total knee arthroplasty.

Femorotibial alignment is an important factor affecting patient outcome after total knee arthroplasty (TKA). It was the aim of this study to report our first results using a CT-based navigation system in two-stage revision surgery for infected TKA. Two patients with chronic deep infection after primary TKA underwent two-stage revision arthroplasty with temporary articulating cement spacers foll...

متن کامل

A computer-assisted, tibia-first technique for improved femoral component rotation in total knee arthroplasty

Background The use of navigation for total knee arthroplasty (TKA) improves limb alignment in the coronal and sagittal planes. However, similar improvements in femoral and tibial component rotation have not yet been realized using currently available systems. Methods We developed a modified navigated TKA technique in which femoral rotation was set using the resected tibial plane as the refere...

متن کامل

Restoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases

Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 90 8  شماره 

صفحات  -

تاریخ انتشار 2008