Indicators of the maximum radiation dose to the skin during percutaneous coronary intervention in different target vessels.
نویسندگان
چکیده
OBJECTIVES To evaluate whether the maximum radiation dose to the patient's skin (MSD) can be estimated during percutaneous coronary intervention (PCI) procedures, we investigated the relationship between the MSD and fluoroscopic time, dose-area product (DAP), and body weight, separately analyzing the relationships for different target vessels. BACKGROUND Many cases of skin injury caused by excessive radiation exposure during cardiac intervention procedures have been reported. However, real-time maximum-dose monitoring of the skin is unavailable for many cardiac intervention procedures. METHODS We studied 197 consecutive PCI procedures that involved a single target vessel and were conducted. The DAP was measured, and the MSD was calculated by a skin-dose mapping software program (Caregraph). The target vessels of the PCI procedures were divided into four groups based on the AHA classification system: AHA 5-10, left anterior descending artery domain (LAD), AHA 11-15, left circumflex artery domain (LCx), AHA 1-3 = R 1-3, and AHA 4 = R 4. RESULTS The correlation coefficient (r) between the MSD and fluoroscopic time was higher for the right coronary artery (RCA) vessels (R 1-3, 0.852; R 4, 0.715) than for the left coronary artery (LCA) vessels (LAD, 0.527; LCx, 0.646), and the r value between the MSD and DAP was higher for the RCA vessels (R 1-3, 0.871; R 4, 0.898) than for the LCA vessels (LAD, 0.628; LCx, 0.694). Similarly, the correlation coefficient between the MSD and weight x fluoroscopic time (WFP) was higher for the RCA vessels (R 1-3, 0.874; R 4, 0.807) than for the LCA vessels (LAD, 0.551; LCx, 0.735). CONCLUSIONS The DAP and WFP can be used to estimate the MSD during PCI in the RCA but not in the LCA, especially the LAD.
منابع مشابه
Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)
Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...
متن کاملOverview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملPatient dose values during interventional cardiology examinations in Yazd hospital, Iran
Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...
متن کاملThe Relation of Serum Bilirubin Level with the Severity and Complexity of Coronary Artery Disease and Long-term Outcomes in the Patients Undergoing Primary Percutaneous Coronary Intervention
Background and Aims: Bilirubin has been considered an antioxidant that protects against atherosclerosis. The aim of this study was to evaluate the relationship of serum bilirubin level with the severity and complexity of coronary artery disease (CAD) and long-term outcome in the patients undergoing primary percutaneous coronary intervention (PCI). Materials and Methods: This prospective coho...
متن کاملRadiation exposure to patient's skin during percutaneous coronary intervention for various lesions, including chronic total occlusion.
BACKGROUND Radiation skin injuries have been reported as a result of various procedures, so in the present study the patients' entrance skin dose (ESD) during percutaneous coronary intervention (PCI) was evaluated. METHODS AND RESULTS ESDs were assessed during 97 procedures (13 for chronic total occlusion (CTO), 14 for multivessel stenoses, 22 for single-vessel multiple stenoses, and 48 for s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
دوره 68 2 شماره
صفحات -
تاریخ انتشار 2006