Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.

نویسندگان

  • R N Low
  • I R Francis
  • R J Herfkens
  • R B Jeffrey
  • G M Glazer
  • T K Foo
  • A Shimakawa
  • N J Pelc
چکیده

OBJECTIVE The purpose of this study was to optimize a new rapid-acquisition MR pulse sequence, called fast multiplanar spoiled gradient-recalled (FMPSPGR) imaging, for breath-hold imaging of the liver and to compare unenhanced and contrast-enhanced FMPSPGR with standard spin-echo imaging in detecting liver tumors. MATERIALS AND METHODS The pulse sequence was optimized at 1.5 T with a healthy volunteer. Various scanning parameters were evaluated, and liver-spleen signal difference/noise measurements were used to estimate lesion contrast-to-noise ratios. We examined 24 patients with hepatic masses using the optimized sequence with spin-echo T1-weighted and T2-weighted imaging as well as unenhanced and gadopentetate dimeglumine-enhanced FMPSPGR imaging. The contrast-to-noise ratio for the hepatic tumors was determined for each sequence. Three radiologists who did not know the biopsy or test results reviewed all images for lesion conspicuity, lesion tissue specificity, and overall image quality. RESULTS A comparison of unenhanced FMPSPGR images with spin-echo T1-weighted images showed a 40% improvement in mean contrast-to-noise ratio and a 70% improvement in liver signal-to-noise ratio for the FMPSPGR images. A comparison of gadopentetate dimeglumine-enhanced FMPSPGR images with spin-echo T1- and T2-weighted images showed a superior contrast-to-noise ratio for the enhanced FMPSPGR images in 17 (68%) of 25 hepatic lesions, which included all hepatic cysts (n = 3) and all hepatomas (n = 6), and in six of 12 patients with other liver tumors. The results of contrast-to-noise ratio for four patients with hemangiomas were mixed. For the remaining eight lesions, the contrast-to-noise ratio for spin-echo T1- and T2-weighted images predominated in three and five cases, respectively. Contrast-enhanced FMPSPGR images revealed a 40% and 300% increase in contrast-to-noise ratio compared with T2- and T1-weighted images, respectively. All three radiologists preferred the contrast-enhanced FMPSPGR images for overall image quality. For lesion conspicuity and specificity, however, the three radiologists differed, with a preference for the FMPSPGR images in 52%, 80%, and 40% of cases for lesion conspicuity and in 68%, 40%, and 60% of cases for lesion specificity. CONCLUSION FMPSPGR is a new, ultrafast MR sequence that provides T1-weighted images of the liver during suspended respiration. Contrast-to-noise ratio and liver signal-to-noise ratio are significantly improved over those on conventional spin-echo T1-weighted images. The combination of breath-hold FMPSPGR with gadopentetate dimeglumine is an excellent technique that can be used to rapidly evaluate the liver with superior overall image quality. Contrast-to-noise ratios are generally superior to T2-weighted spin-echo images, making this technique a useful adjunct to conventional spin-echo MR imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR imaging of joints: analytic optimization of GRE techniques at 1.5 T.

To clarify the choice of imaging parameters for optimal gradient-recalled echo MR scanning of joints, we analyzed the behavior of contrast-to-noise and signal-to-noise ratios for spoiled (i.e., fast low-angle shot [FLASH] or spoiled GRASS) and steady-state (i.e., gradient-recalled acquisition in the steady state [GRASS] or fast imaging with steady precession) techniques at 1.5 T. The analysis i...

متن کامل

Optimal Pulse Sequence for Ferumoxides-Enhanced MR Imaging Used in the Detection of Hepatocellular Carcinoma: A Comparative Study Using Seven Pulse Sequences

OBJECTIVE To identify the optimal pulse sequence for ferumoxides-enhanced magnetic resonance (MR) imaging in the detection of hepatocelluar carcinomas (HCCs). MATERIALS AND METHODS Sixteen patients with 25 HCCs underwent MR imaging following intravenous infusion of ferumoxides. All MR studies were performed on a 1.5-T MR system, using a phased-array coil. Ferumoxides (Feridex IV) at a dose of...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Difference in enhancement between spin echo and 3-dimensional fast spoiled gradient recalled acquisition in steady state magnetic resonance imaging of brain metastasis at 3-T magnetic resonance imaging.

OBJECTIVE To compare the enhancement of brain metastasis between 3-dimensional fast spoiled gradient recalled acquisition in the steady state (3DFSPGR) and spin echo (SE) T1-weighted imaging at 3-T magnetic resonance imaging. METHODS The subjects comprised 18 patients with 81 suspected brain metastases. Axial SE and 3DFSPGR images were obtained before and after gadoteridol injection. The sign...

متن کامل

Gradient echo imaging.

Magnetic resonance imaging (MRI) based on gradient echoes is used in a wide variety of imaging techniques and clinical applications. Gradient echo sequences form the basis for an essential group of imaging methods that find widespread use in clinical practice, particularly when fast imaging is important, as for example in cardiac MRI or contrast-enhanced MR angiography. However, the term "gradi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 160 3  شماره 

صفحات  -

تاریخ انتشار 1993