Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis.
نویسندگان
چکیده
BACKGROUND In animal studies of radiofrequency ablation, lesion sizes plateau as the maximum lesion size is reached for an ablation. Lesion parameters are not available in clinical ablations, but preclinical work suggests that these correlate with impedance drop and electrogram attenuation. Characterization of the relationships between catheter contact force, ablation duration, and these surrogate markers of lesion formation may allow us to define targets for effective ablation. METHODS AND RESULTS Fifteen patients undergoing first-time radiofrequency ablation for nonparoxysmal atrial fibrillation were studied. All were in atrial fibrillation at the time of the procedure. Ablations were performed with an irrigated-tip contact force-sensing catheter in temperature-controlled mode (temperature limited to 48°C, power to 30 W). Included were 285 left atrial static ablations, 247 with additional impedance data. The ablation force time integral (FTI) correlated with the attenuation of the electrogram with ablation (Spearman ρ, -0.14; P=0.02): the relationship plateauing from 500 g·s, a reduction in the electrogram amplitude of 20%. The FTI also correlated with the impedance drop during ablation (Spearman ρ, 0.79; P<0.0005): the relationship was logarithmic, the reduction in the impedance with an increasing FTI also plateauing from 500 g·s, an impedance drop of 7.5%. The ablation duration affected the impedance drop at an FTI if the duration was <10 s. Beyond this time point, the FTI achieved rather than the ablation duration or mean contact force applied determined the impedance drop. CONCLUSIONS During nonparoxysmal atrial fibrillation ablation, an FTI of 500 g·s should be targeted with ablation duration of ≥10 s. Clinical Trials Registration- URL: http://clinicaltrials.gov/. Unique Identifier: NCT01587404.
منابع مشابه
Impact of Catheter Contact Force on Human Left Atrial Electrogram Characteristics in Sinus Rhythm and Atrial Fibrillation.
BACKGROUND During left atrial mapping, optimal contact parameters minimizing variation secondary to catheter contact are not established. METHODS AND RESULTS Across 30 patients undergoing first-time atrial fibrillation ablation, 1965 stable mapping points (1409 atrial fibrillation, 556 sinus rhythm), comprising 8-s contact force (CF) and bipolar electrogram data were analyzed. Points were tak...
متن کاملEffect of pacing site on the atrial electrogram at target sites for slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia.
Atrial electrograms recorded from target sites during radiofrequency catheter ablation of the slow atrioventricular (AV) nodal pathway are often fractionated and may be associated with a late, high frequency component (the slow pathway potential). The purpose of the current study was to assess the effects of slow pathway ablation on the morphology of the atrial electrogram and to determine whet...
متن کاملContact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions.
AIMS During radiofrequency (RF) delivery, lesion volume is highly dependent on contact force (CF). It has recently been shown that changes of bipolar electrogram (EGM) predict transmurality. We hypothesized that there is a correlation between CF and EGM criteria of transmural lesion (TL) during RF. METHODS AND RESULTS We prospectively studied consecutive 512 RF applications from atrial fibril...
متن کاملTemperature-controlled slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia using a combined anatomical and electrogram guided strategy.
AIMS Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the s...
متن کاملLocations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation.
BACKGROUND During radiofrequency ablation, high electrode-tissue contact force (CF) is associated with increased risk of steam pop and perforation. The purpose of this study, in patients undergoing ablation of paroxysmal atrial fibrillation, was to: (1) identify factors producing high CF during left atrial (LA) and pulmonary vein mapping; (2) determine the ability of atrial potential amplitude ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2014