Hearing and Otoacoustic Emissions Outcome of Stapedotomy: Does the Prosthesis Diameter Matter?
نویسندگان
چکیده
OBJECTIVE To compare the hearing and otoacoustic emissions (OAE) outcome of stapedotomy employing 0.4 and 0.6 mm diameter prostheses. MATERIALS AND METHODS In total, 18 patients with otosclerosis participated in a prospective, double-armed, randomized cohort study. All the patients underwent small fenestra drill stapedotomy employing the Causse fluroplastic large loop piston prostheses. The patients were randomly assigned to groups of 0.4 mm (n=9) and 0.6 mm (n=9) diameter prostheses. The results of pure tone air and bone audiometries, speech audiometry, and OAE conducted 12 months post operatively were compared within and between the groups. RESULTS The within-group analysis showed significant post-stapedotomy improvements in the average air conduction pure tone thresholds in both groups (52.9±9.6 vs. 25.6±5.2 dB HL; p<0.0001 and 54.6±10.4 vs. 22.2±8.2 dB HL; p<0.0001 for the 0.4 and 0.6 mm groups, respectively) and average air-bone gap (ABG; 37.1±8.5 vs. 8.1±3.9 dB HL; p<0.0001 and 38.3±7.5 vs. 9.9±4.5 dB HL; p<0.0001 in the 0.4 and 0.6 mm groups, respectively). No significant differences were found between the groups in these outcome measures, as well as in the rate of ABG closure within 10 dB HL and the word recognition scores. Favorable outcome in the post-stapedotomy bone conduction (BC) was found for the 0.6 mm prosthesis group, reflecting superior cancellation of the Carhart phenomenon for the 500-3000 Hz pure tone thresholds average (-1.7±3.7 vs. 3.9±6.2 dB HL for the 0.4 and 0.6 mm groups, respectively; p<0.04) and 1000, 2000, and 4000 Hz average (-2.6±4.33 vs. 3.9±7.8 dB HL for the 0.4 and 0.6 mm groups, respectively; p<0.05). Small signal-to-noise ratio (SNR) values of the transient-evoked OAE (TEOAE) and distortion product OAE (DPOAE) were found at baseline and follow-up evaluation with no consistent changes post stapedotomy. CONCLUSION Similar post-stapedotomy hearing results were found for the 0.4 and 0.6 mm prostheses with small but statistically significant advantage in BC gain and the overclosure parameter for the 0.6 mm prosthesis. OAE testing was not found to be of clinical value in the evaluation of stapedotomy hearing outcome.
منابع مشابه
Objective Evaluation of the Prosthesis Diameter on Hearing Results after Stapedotomy
stapedotomy. Materials and Methods: The diameters of prostheses used were 0.3 mm and 0.6 mm in two groups of ten patients. and 10 healthy patients as control group were included. Transient evoked otoacoustic emissions (TEOAE), Distortion product otoacoustic emissions (DPOAE) and DPOAE I/O functions were recorded. Results: Significant changes were detected at 2000-3000 Hz (p<0.001) and 4000-6000...
متن کاملThe Profile of Otoacoustic Emissions and Multifrequency Tympanometry in Otosclerotic Patients Undergoing Two Types of Stapes Surgery: Small Fenestra and Microtraumatic Stapedotomy
BACKGROUND Otoacoustic emissions (OAEs) are influenced in otosclerosis. The aim of the current study was to investigate the profile of transient evoked (TEOAEs) and distortion product otoacoustic emissions (DPOAEs) in association with multifrequency tympanometry measures in otosclerotic patients undergoing 2 types of stapes surgery: small fenestra and microtraumatic stapedotomy. MATERIAL AND ...
متن کاملThe relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus
Background: The possible role of cochlear function in tinnitus generation is still a matter of debate. To assess the role of outer hair cell dysfunction in tinnitus and its possible relationship with ultra-high frequency (UHF) hearing sensitivity, transient evoked otoacoustic emissions (TEOAE) and UHF hearing thresholds were investigated in normal hearing individuals with and withou...
متن کاملOtoacoustic Emissions in Sudden Sensorineural Hearing Loss: Changes of Measures with Treatment
Introduction: To identify changes in OAEs parameters in treatment course of idiopathic sudden sensorineural hearing loss (iSSNHL). Materials and Methods: In aprospective studyfromAugust 2005 to January 2009, 26 patients with iSSNHL underwent conventional audiometry/tympanometry and two types of OAEs (TEOAEs and DPOAEs) before and after the completion of standard drug therapy.The changes in p...
متن کاملComparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy
Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of international advanced otology
دوره 13 2 شماره
صفحات -