Active Electrode Based Electrical Impedance Tomography System

نویسندگان

  • Pascal O. Gaggero
  • Andy Adler
  • Josef X. Brunner
  • Stephan Böhm
  • Peter Seitz
چکیده

Abstract: EIT can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key di culties in EIT instrumentation make such monitoring di cult: 1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, and 2) EIT electrodes are di cult and time consuming to place on patients. This paper presents the design and initial tests of an active electrode based system to address these di culties. An electrode belt is designed incorporating 32 active electrodes, each of which contains the electronic ampli ers, switches and associated logic. Tests show stable device performance with a conventient ease of use and good imaging ability in volunteer tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical impedance tomography system based on active electrodes.

Electrical impedance tomography (EIT) can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key difficulties in EIT instrumentation make such monitoring difficult: (1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, a...

متن کامل

Fast EIT data acquisition system with active electrodes and its application to cardiac imaging.

A wide-band high-speed data acquisition system for electrical impedance tomography (EIT) is described. 32 active electrodes are used in the system, half of them as receive electrodes and the other half as drive electrodes. A buffer is mounted on the back of each receive electrode and a current source on each drive electrode. A multielectrode system with active electrodes was built to make it co...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Direct calculation of the electrode movement Jacobian for 3D EIT

Electrical Impedance Tomography (EIT) of media with deformable boundaries is very sensitive to electrode movement. This is especially important for EIT images of the thorax, which become distorted with breathing and posture change. Previously, we proposed a reconstruction method for imaging conductivity change and electrode movement based on an indirect perturbation Jacobian calculation, involv...

متن کامل

Further investigation of a contactless patient-electrode interface of an Electrical Impedance Mammography system

The Sussex Mk4 Electrical Impedance Mammography (EIM) system is a novel instrument, designed for the detection of early breast cancer, based upon Electrical Impedance Tomography (EIT). Many innovations in the field have been incorporated in the design improving both signal distribution and response. This paper investigates the behaviour of the contactless patient-electrode interface. The interf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011