Comparison of calculated dose by helical tomotherapy treatment planning machine and measured dose of radiophotoluminescence glass dosimeter in lung lesions using Rando Phantom.
نویسندگان
چکیده
AIM To examine the compatibility of the measured and calculated dose for the treatment of lung lesions by helical tomotherapy. MATERIALS AND METHODS The administered dose was measured a total of 55 times at 22 points with a radiophotoluminescence glass dosimeter (RPLGD) inserted in the position of an anthropomorphic Rando Phantom. Two Gy were prescribed and calculated with a tomotherapy planning machine for a 3-cm diameter spherical planning target volume (PTV) created in the lung area. Compatibility (measured dose/calculated dose and σ value=(D(meas)-D(calc))/D(prescribed)) × 100 (%)) was analyzed according to dosimeter location. RESULTS Deviations between measured and calculated doses for the lung lesion were within 4% for planning target volume, indicating that adequate dose delivery to the PTV was achievable. On the other hand, we found dose deviations up to 15% for the lower prescribed dose range (64% or less) for the measured dose/calculated comparison and a 6% deviation according to the σ value in or near inhomogeneous tissue. CONCLUSION Although the measured dose satisfied the clinical requirement in almost all areas including PTV, we should note that there may be discrepancies between expected calculated dose and irradiated dose in or near inhomogeneous area.
منابع مشابه
Small field size dose-profile measurements: A comparison between Eclipse™ treatment planning system with NIPAM polymer gel dosimeter dose measurement
Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...
متن کاملComparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom
Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملEvaluation of Breast Cancer Radiation Therapy Techniques in Outfield Organs of Rando Phantom with Thermoluminescence Dosimeter
Background: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured.Objective: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. Methods: Eight diff...
متن کاملDosimetric accuracy of tomotherapy dose calculation in thorax lesions
BACKGROUND To analyse limits and capabilities in dose calculation of collapsed-cone-convolution (CCC) algorithm implemented in helical tomotherapy (HT) treatment planning system for thorax lesions. METHODS The agreement between measured and calculated dose was verified both in homogeneous (Cheese Phantom) and in a custom-made inhomogeneous phantom. The inhomogeneous phantom was employed to mi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anticancer research
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2013