Hemoglobin A1c and Mean Glucose in Patients With Type 1 Diabetes

نویسندگان

  • Darrell M Wilson
  • Dongyuan Xing
  • Roy W Beck
  • Jennifer Block
  • Bruce Bode
  • Larry A Fox
  • Irl Hirsch
  • Craig Kollman
  • Lori Laffel
  • Katrina J Ruedy
  • Michael Steffes
  • William V Tamborlane
چکیده

OBJECTIVE To determine the relationship between mean sensor glucose concentrations and hemoglobin A(1c) (HbA(1c)) values measured in the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications laboratory at the University of Minnesota in a cohort of subjects with type 1 diabetes from the Juvenile Diabetes Research Foundation continuous glucose monitoring randomized trial. RESEARCH DESIGN AND METHODS Near-continuous glucose sensor data (≥ 4 days/week) were collected for 3 months before a central laboratory-measured HbA(1c) was performed for 252 subjects aged 8-74 years, the majority of whom had stable HbA(1c) values (77% within ± 0.4% of the patient mean). RESULTS The slope (95% CI) for mean sensor glucose concentration (area under the curve) versus a centrally measured HbA(1c) was 24.4 mg/dL (22.0-26.7) for each 1% change in HbA(1c), with an intercept of -16.2 mg/dL (-32.9 to 0.6). Although the slope did not vary with age or sex, there was substantial individual variability, with mean sensor glucose concentrations ranging from 128 to 187 mg/dL for an HbA(1c) of 6.9-7.1%. The root mean square of the errors between the actual mean sensor glucose concentration versus the value calculated using the regression equation was 14.3 mg/dL, whereas the median absolute difference was 10.1 mg/dL. CONCLUSIONS There is substantial individual variability between the measured versus calculated mean glucose concentrations. Consequently, estimated average glucose concentrations calculated from measured HbA(1c) values should be used with caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of 6 Isocaloric Meals Pattern on Blood Lipid Profile, Glucose, Hemoglobin A1c, Insulin and Malondialdehyde in Type 2 Diabetic Patients: A Randomized Clinical Trial

Background: The present clinical trial study aims at investigating the effect of daily energy intake in 6 isocaloric meals in comparison with the current meal pattern (3 meals and 2 small snacks per day) on type 2 diabetes risk markers in diabetes during 3-month period. Methods: Eighty four type 2 diabetes patients were randomly divided into 6 isocaloric meal diet or a balanced diet (3 meals an...

متن کامل

Efficacy of adding glutazone to the maximum dose of glibenclamide and metformin resistant on type 2 diabetic patients

Background: To evaluate the efficacy of adding the glutazone to maximum dose of sulfonylurea and metformin in patients with poorly controlled type 2 diabetes. Methods: Ninety six patients with type 2 diabetes who had failed medical therapy with maximal-dosage of metformin and glibenclamide received glutazone. Fasting blood sugar (FBS), 2 hours postprandial (2hpp) glucose, hemoglobin A1C, chol...

متن کامل

Diagnostic Value of Fructosamine and Glycosylated Hemoglobin in Estimating Blood Glucose Level in Diabetic Patients with Thalassemia Major

Abstract Background and Objective: Diabetes mellitus is one of complications that thalassemia major patients face with. Hence, blood glucose monitoring is of vital importance to these patients. Because of high level of fetal hemoglobin in these patients, the measurement of hemoglobin A1c is not reliable and should be displaced by fructosamine test. Material and Methods: The current descr...

متن کامل

Effect of Chromium Supplementation on Blood Glucose, Hemoglobin A1c, Lipid Profile and Lipid Peroxidation in Type 2 Diabetic Patients

Objective: Type 2 diabetes mellitus is a complex metabolic disorder with adverse cardiovascular risk. Chromium (Cr) is an essential nutrient and its role in carbohydrate and lipid metabolism has not been clarified especially in Iran. The aim of this study was to evaluate the effect of chromium picolinate administration on blood glucose, HbA1c, lipid profile and lipid peroxidation in type 2 diab...

متن کامل

Effects of Coenzyme Q10 on Hemoglobin A1C, Serum Urea and Creatinine in Alloxan-Induced Type 1 Diabetic Rats

Coenzyme Q 10 is a natural antioxidant and free radicals scavenger. In the present study, we examined effect of coenzyme Q 10 on hemoglobin A 1C , serum urea and creatinine in alloxan-induced Type 1 diabetic rats. Thirty Sprage-Dawley male rats were divided into three groups randomly; group one as control, group two diabetic untreatment, and group three treatments with coenzyme Q ...

متن کامل

بررسی شاخص های مرتبط با کیفیت مراقبت بیماران دیابتی تحت پوشش برنامه پزشک خانواده روستایی شهرستان ارومیه در سال 1396

Background & Aims: More than 382 million people in the world live with diabetes, 80% of whom live in low-income and developing countries. Today, it is quite clear that improving metabolic control in diabetic patients can reduce the complications of the disease. The purpose of this study was to evaluate the quality of care associated with diabetic patients under the coverage of Urmia rural famil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2011