Optimizing the concentration of 2,4,6-trimethylbenzoyldiphenylphosphine oxide initiator in composite resins in relation to monomer conversion.
نویسندگان
چکیده
The aim of this study was to optimize the concentration of 2,4,6-trimethylbenzoyldiphenylphosphine oxide (Lucirin® TPO) in unfilled and filled composite resins in relation to the degree of conversion (DC). Increasing concentrations of Lucirin® TPO between 0.05-4.97 wt% were added to equimolar mixtures of Bis-GMA/TEGDMA. Filled resins contained 75 wt% fillers. Standardized samples were cured using a polywave LED light-curing unit (bluephase® G2, Ivoclar Vivadent). Increased initiator concentrations increased logarithmically the DC of unfilled and filled resins. The DC of unfilled resins was in the range of 73-91% at the top and 63-81% at the bottom surfaces and that of filled resins was in the range of 53-81% at the top and 47-70% at the bottom surfaces. The DC in unfilled and filled resins reached a plateau at 1.08 wt% and 1.50 wt% Lucirin® TPO, respectively. Fillers significantly reduced conversion but had no effect on the logarithmic relationship between initiator concentration and the DC.
منابع مشابه
The evaluation of residual monomer released after polymerization of four different composite resins
Purpose: The aim of this study is to compare the amount of Bis-GMA, UDMA, and TEGDMA released from four different types of composite resins in three different time periods using the HPLC device. Materials and Methods: Four different composite resin materials with nanofiller content were used in the study. A total of 40 sample discs were prepared and polished to provide 10 pieces for each mater...
متن کاملDetermination of Residual Methylmethacrylate Monomerin Denture Base Resins by Gas Chromatography
Acrylic base resins are widely used in orthopedics and dental surgery. It is generally accepted that due to the incomplete conversion of methyl methacrylate (MMA) monomer to the polymer form during polymerization of the resin, some MMA monomers remain in the hardened material. MMA monomer has been reported to cause abnormalities or lesions in several organs of animals. Study of the literatures ...
متن کاملDetermination of Residual Methylmethacrylate Monomerin Denture Base Resins by Gas Chromatography
Acrylic base resins are widely used in orthopedics and dental surgery. It is generally accepted that due to the incomplete conversion of methyl methacrylate (MMA) monomer to the polymer form during polymerization of the resin, some MMA monomers remain in the hardened material. MMA monomer has been reported to cause abnormalities or lesions in several organs of animals. Study of the literatures ...
متن کاملSynthesis of Magnetic Graphene Oxide Nanocomposite for Adsorption Removal of Reactive Red 195: Modelling and Optimizing via Central Composite Design
In this work, magnetic graphene oxide (MGO) was prepared by in situ synthesis of magnetite nanoparticles in the presence of graphene oxide (GO). The prepared nanocomposite was characterized by applying scanning electron microscopy (SEM), X-ray diffraction (XRD, Fourier transform infrared spectroscopy (FTIR) and vibrating sample magnetometer (VSM). MGO was applied as an ...
متن کاملسنتز پلیمرهای قالب ملکولی تریازینی: به عنوان فناوری نوین پایش آلاینده های ریزمقدار شغلی
Background and Objective: Biological adsorbents under undesirable conditions have not suitable performance. Based on this problem, the using of the molecular imprinted polymers (MIPs) have been proposed. This study was conducted to adsorption of trace triazinic pesticides with synthesis and optimization of molecular imprinted polymers as a novel solid phase extraction (MISPE). ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Dental materials journal
دوره 31 5 شماره
صفحات -
تاریخ انتشار 2012