Serum aminoglycoside assay by enzyme-mediated immunoassay (EMIT): correlation with radioimmunoassay, microbiological assays.
نویسندگان
چکیده
Enzyme-mediated immunoassay (EMIT) serum aminoglycoside assay results were accurate and precise and correlated well with radioimmunoassay, fluoroimmunoassay, and acetyltransferase and microbiological assay determinations.
منابع مشابه
Determination of methotrexate in serum by a rapid, fully mechanized enzyme immunoassay (EMIT).
A homogeneous enzyme immunoassay for the determination of methotrexate in serum (EMIT, Syva Corp.) was fully mechanized by the use of an Eppendorf analyzer 5010. Coefficients of variation from day to day were in the range 2--16%. A comparison of the results obtained by EMIT and a radioimmunoassay (Methotrexate 125 I Radioimmunoassay Kit, Diagnostic Biochemistry Inc.) in a series of 50 samples f...
متن کاملEvaluation of the manual enzyme immunoassay (EMIT) procedure for determination of serum thyroxine.
Our experience with the determination of thyroxine (T4) in serum using a homogeneous enzyme immunoassay technique (EMIT, Syva Corp.) is reported. The intra-assay precision of the EMIT Manual Thyroxine Assay was investigated with 2 different calibrator concentrations and showed coefficients of variation varying from 5--2% for thyroxine concentrations of 40 and 120 micrograms/l thyroxine respecti...
متن کاملEvaluation of enzyme-multiplied immunoassay technique (EMIT) for determination of serum digoxin.
Sixty-seven digoxin-containing sera were analyzed by both radioimmunoassay and EMIT. After some important modifications of the EMIT method, agreement between the two methods was very good. Reproducibility of the EMIT assay was excellent; daily variations in values found for control sera were quite small, and recovery of added digoxin was good. Slight hemolysis hadnegligible effects, but highly ...
متن کاملEnzyme immunoassay and enzyme inhibition assay of methotrexate, with use of the centrifugal analyzer.
Methotrexate was determined by the homogeneous enzyme immunoassay (EMIT) with the Multistat and CentrifiChem centrifugal analyzers and by the enzyme inhibition assay with use of the Multistat centrifugal analyzer. With both methods, the standard curve extends from 0.2 to 2.0 mumol/L and there is no interference from bilirubin in concentrations up to 100 mg/L. Moderately lipemic samples do not i...
متن کاملComparative assessment of in vitro inactivation of gentamicin in the presence of carbenicillin by three different gentamicin assay methods.
Inactivation of gentamicin (G) is known to occur secondarily to the formation of complexes with certain beta-lactam antibiotics. However, aminoglycosides in the presence of aminoglycoside-beta-lactam complexes may not be recognized uniformly by all assay methods. We tested this hypothesis by using mixtures of G plus carbenicillin (C), with and without the addition of penicillinase, in pooled se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 19 6 شماره
صفحات -
تاریخ انتشار 1981