A simple approach of three-isocenter IMRT planning for craniospinal irradiation
نویسندگان
چکیده
PURPOSE To develop a new IMRT technique to simplify the process and improve efficiency in radiotherapy treatment planning for craniospinal irradiation (CSI) treatment. METHODS Image data of 9 patients who received CSI treatment in 2012 were used, the prescription was 36Gy in 20 fractions. Two treatment plans were created for each patient, one was with the new technique called three-isocenter overlap-junction (TIOJ) IMRT and the other was with the three-isocenter jagged-junction (TIJJ) IMRT technique. The comparative study was conducted using the parameters of heterogeneity index (HI), conformity index (CI), and doses to the organs at risk (OARs). RESULTS Comparing the TIOJ IMRT plans with the TIJJ IMRT plans, the average homogeneity index is 0.071 ± 0.003 and 0.077 ± 0.002, respectively, and the averaged conformity number is 0.80 ± 0.012 and 0.80 ± 0.009, respectively. There are no significant differences (p > 0.05). Both plans provide satisfactory sparing for the OARs. CONCLUSIONS The TIOJ IMRT technique for CSI treatment planning can create similar plans as with the TIJJ IMRT technique, but the new technique greatly simplifies the steps required to manually set field widths and boundaries and improved efficiency.
منابع مشابه
Practical dose delivery verification of craniospinal IMRT
Craniospinal irradiation (CSI) using IMRT allows dose sparing to organs-at-risk (OAR) whilst conforming the dose to the target volume. Due to the complexity of treatment involving several isocenters, the dose distribution created by the inverse-planned segmented fields must be verified prior to treatment. We propose and test methods to verify dose delivery using commonly available dosimetry equ...
متن کاملCraniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
Background: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric plans in which the junction is shifted after every five fractions to overcome the possibility of hot and cold spot.Objective: This study aims to evaluate dosimetrically and cli...
متن کاملA simple technique for craniospinal radiotherapy in the supine position.
PURPOSE Craniospinal irradiation poses technical difficulties that may be addressed with the use of the newer technologies that have become available over the past decade. The use of CT simulation allows improved target localisation and beam geometry definition while significantly reducing the treatment simulation time. We have developed a CT-based technique for whole CNS irradiation in the sup...
متن کاملSingle‐isocenter hybrid IMRT plans versus two‐isocenter conventional plans and impact of intrafraction motion for the treatment of breast cancer with supraclavicular lymph nodes involvement
The purpose of this study was to compare the single-isocenter, four-field hybrid IMRT with the two-isocenter techniques to treat the whole breast and supraclavicular fields and to investigate the intrafraction motions in both techniques in the superior direction. Fifteen breast cancer patients who underwent lumpectomy and adjuvant radiation to the whole breast and supraclavicular (SCV) fossa at...
متن کاملTechnique for sparing previously irradiated critical normal structures in salvage proton craniospinal irradiation
BACKGROUND Cranial reirradiation is clinically appropriate in some cases but cumulative radiation dose to critical normal structures remains a practical concern. The authors developed a simple technique in 3D conformal proton craniospinal irradiation (CSI) to block organs at risk (OAR) while minimizing underdosing of adjacent target brain tissue. METHODS Two clinical cases illustrate the use ...
متن کامل