Test-Quality Comparison between Full- Scan, Partial-Scan and On-Line Techniques for a Periodic Synchronizer

نویسندگان

  • Octavian Petre
  • Hans G. Kerkhoff
چکیده

-Because of shrinking minimum feature sizes, IC clock frequencies are increasing. It is no longer possible, nor desired, to distribute a single clock over the entire IC. Multipleclock domains design will no longer be an isolated design style. This new trend in the industry, referred to as future standard by some companies, poses many test problems due to special modules utilized at the interface between clock domains. These modules are called synchronizers. This paper will present and compare different test strategies used for testing multiple-clock domain systems in general and synchronizers in particular. Keywords--full-scan testing, partial-scan testing, on-line testing, periodic synchronizer

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

ارزش پیش‌بینی‌کننده استرس تست و اسکن پرفیوژن میوکارد در گروه‌های سنی مختلف بر اساس نتایج آنژیوگرافی کرونر

Background: The most common methods for screening of patients with probable ischemic heart disease are stress test and in special conditions are perfusion scan, so that their positive results was important indication of coronary angiography. Although, predictive value of perfusion scan has been considered, with regard to the impact of technical and specialized factors and according to the sprea...

متن کامل

بررسی 110 مورد هیپرپاراتیروئیدی اولیه در بیمارستان دکتر شریعتی و نتایج لوکالیزاسیون آدنوم توسط اسکن MIBI

Primary Hyperparathyroidism is a fairly common disease that is much more predominant in females. Treatment is surgery and includes removing the parathyroid adenoma or the hyperplastic parathyroid glands. Considering the difficulty of this operation procedure, localization test are utilized including ultrasound, MRI, CT scan, Thallium-Technesium subtraction scan, MIBI scan and a series of other ...

متن کامل

An Application of Partial Scan Techniques to a High-End System LSI Design

In large and high-speed LSI designs, the area and delay overhead of the design-for-test (DFT) circuit must be minimized while keeping sufficient testability. Partial scan is one of the techniques that can reduce the overhead of full scan. However, it is not simple to apply the partial scan method to large designs because of its long design turn-around-time (TAT) and pattern length. This paper p...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001