The impedance threshold device (ITD-7)--a new device for combat casualty care to augment circulation and blood pressure in hypotensive spontaneously breathing warfighters.

نویسندگان

  • Don Parsons
  • Vic Convertino
  • Ahamed Idris
  • Stephen Smith
  • David Lindstrom
  • Brent Parquette
  • Tom Aufderheide
چکیده

Inspiration through -7cm H2O resistance results in an increase in venous blood flow back to the heart and a subsequent increase in cardiac output and blood pressure in hypotensive animals and patients. Breathing through the impedance threshold device with 7cm H2O resistance (ITD-7) also reduces intracranial pressure with each inspiration, thereby providing greater blood flow to the brain. A new device called an ITD-7 was developed to exploit these physiological mechanisms to buy time in hypotensive War Fighters when other therapies are not readily available. Animal and clinical data with the ITD-7 demonstrate the potential value and limitations of this new non-invasive approach to enhancing circulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of respiratory impedance in prehospital care of hypotensive patients associated with hemorrhage and trauma: a case series.

BACKGROUND The respiratory pump can be optimized to enhance circulation in patients with hypotension by having patients spontaneously breathe through a low level of inspiratory resistance. This can be achieved with an impedance threshold device (ITD) designed to provide 7 cm H2O resistance during spontaneous inspiration with minimal resistance during expiration. Little is known about the effect...

متن کامل

Use of an impedance threshold device in spontaneously breathing patients with hypotension secondary to trauma: an observational cohort feasibility study.

BACKGROUND An impedance threshold device (ITD) intended for use in the spontaneously breathing patient has been shown to raise blood pressure in hypotensive patients. This device has not been evaluated in patients with hypotension secondary to trauma. This study focused on changes in key vital signs when the ITD was added to the paramedic treatment protocol for hypotensive patients with prehosp...

متن کامل

Use of an impedance threshold device to treat severe hypotension in a pregnant woman: case report and review of the literature.

BACKGROUND Impedance threshold device technology harnesses the patient's normal physiological mechanisms to increase circulation during hypotensive crises. We report the first clinical use of one version of this device on a spontaneously breathing hypotensive pregnant woman. OBJECTIVE The objective of our study was to report this case to help Emergency Medical Service rescue personnel to noni...

متن کامل

Inspiratory resistance, cerebral blood flow velocity, and symptoms of acute hypotension.

INTRODUCTION Symptoms of orthostatic intolerance, e.g., following prolonged bed rest and microgravity exposure, are associated with reductions in cerebral blood flow. We tested the hypothesis that spontaneously breathing through an impedance threshold device (ITD) would attenuate the fall in cerebral blood flow velocity (CBFV) during a hypotensive orthostatic challenge and reduce the severity o...

متن کامل

Human autonomic and cerebrovascular responses to inspiratory impedance.

BACKGROUND We evaluated the influence of breathing through an inspiratory Impedance Threshold Device (ITD) on autonomic neural and cerebrovascular function. METHODS Eight subjects breathed through a sham ITD (0 cmH2O) and an active ITD (-7 cmH2O) in the supine position. We recorded the ECG, finger photoplethysmographic arterial pressure, cerebral blood flow velocity, and muscle sympathetic ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of special operations medicine : a peer reviewed journal for SOF medical professionals

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 2009