Rescaled Local Interaction Simulation Approach for Shear Wave Propagation Modelling in Magnetic Resonance Elastography
نویسندگان
چکیده
Properties of soft biological tissues are increasingly used in medical diagnosis to detect various abnormalities, for example, in liver fibrosis or breast tumors. It is well known that mechanical stiffness of human organs can be obtained from organ responses to shear stress waves through Magnetic Resonance Elastography. The Local Interaction Simulation Approach is proposed for effective modelling of shear wave propagation in soft tissues. The results are validated using experimental data from Magnetic Resonance Elastography. These results show the potential of the method for shear wave propagation modelling in soft tissues. The major advantage of the proposed approach is a significant reduction of computational effort.
منابع مشابه
TREMR: Table-resonance elastography with MR.
Magnetic resonance elastography (MRE) is a noninvasive method of measuring tissue compliance. Current MRE methods rely on custom-built hardware to elicit vibrations that are tracked by MR imaging. Knowledge of the wave propagation can be used to calculate the local shear stiffness of the tissue. We sought to determine whether the vibrations of the patient table that result from low-frequency sw...
متن کاملCalculation of shear stiffness in noise dominated magnetic resonance elastography data based on principal frequency estimation.
Magnetic resonance elastography (MRE) is a non-invasive phase-contrast-based method for quantifying the shear stiffness of biological tissues. Synchronous application of a shear wave source and motion encoding gradient waveforms within the MRE pulse sequence enable visualization of the propagating shear wave throughout the medium under investigation. Encoded shear wave-induced displacements are...
متن کاملThree dimensional shear wave scattering MR elastography
Introduction: Magnetic resonance elastography (MRE) is a non invasive method that combines externally applied vibrations with the motion sensitivity of MRI to measure the shear elasticity soft tissues [1]. In MRE this is traditionally achieved by solving an inverse problem with MRE shear wave images as input data [2]. A complementary approach, which does not require the solution of an inverse p...
متن کاملQuantitative shear wave magnetic resonance elastography: comparison to a dynamic shear material test.
Magnetic resonance elastography (MRE), a phase contrast MRI technique, images the propagation of applied mechanical waves in tissue, allowing shear stiffness to be quantified in vivo. This MRE technique has been validated with static mechanical compression tests. Dynamic mechanical analysis (DMA) may be a more appropriate comparison to MRE because it directly measures the shear modulus dynamica...
متن کاملSimulation of wave fields observed in brain MR elastography by 3D finite element analysis
Introduction: Image contrast in magnetic resonance elastography (MRE) is based on mechanical properties of tissues [1]. Recently, there has been an increasing interest in the area of MRE of the brain. So far, MRE has shown to be the only suitable noninvasive method for determining elastic [2-4] and even viscoelastic [5-7] properties of the human brain parenchyma in vivo. However, data reported ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016