Lung Tumor Tracking and Couch Control - A Feasibility Study

نویسنده

  • Alvaro Obregon
چکیده

We look at the problem of real-time tumor tracking and motion compensation in radiotherapy techniques from a pure feedback-control point of view and try to understand it using simple mechanical models of the treatment couch and breathing patterns. Since we want to control a robotic couch based on the data collected in real-time, we propose the use of an acceleration sensor to develop a feedback control system to correct for the random movements of the tumor. An acceleration sensor offers a much richer set of data and in situations of rapid change in the breathing pattern, an acceleration sensor can provide a quick measurement and prediction of the trend. Our simplified models and the prototype show stable response under normal conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback

Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...

متن کامل

Unconscious physiological response of healthy volunteers to dynamic respiration-synchronized couch motion

BACKGROUND Intrafractional motion can be a substantial uncertainty in precision radiotherapy. Conventionally, the target volume is expanded to account for the motion. Couch-tracking is an alternative, where the patient is moved to compensate for the tumor motion. However, the couch motion may influence the patient's stress and respiration behavior decreasing the couch-tracking effectiveness. ...

متن کامل

Modeling and performance evaluation of a robotic treatment couch for tumor tracking.

Tumor motion during radiation therapy increases the irradiation of healthy tissue. However, this problem may be mitigated by moving the patient via the treatment couch such that the tumor motion relative to the beam is minimized. The treatment couch poses limitations to the potential mitigation, thus the performance of the Protura (CIVCO) treatment couch was characterized and numerically modele...

متن کامل

A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates

Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008