Reflecting optical system to increase signal intensity in confocal microscopy
نویسندگان
چکیده
In fluorescence mode confocal microscopes, only 0.02% of emitted signal can be detected in best case. So, we proposed reflecting optical system to increase signal intensity detected in photon detector. In this paper, we evaluate the proposed reflecting optical system using optical transfer function. To evaluate the proposed system, we used the modeling method based on wave optics. We first calculated point spread function of total system, and calculated optical transfer function of total system. When we use the proposed reflecting optical system, we can increase the signal intensity detected in photon detector. Amount of increased signal intensity depends on the ratio of NA of objective in the original confocal microscopy to NA of objective in reflecting optical system. We also simulated axial response of total system. FWHM of axial response increased a little when using reflecting optical system. The amount of increased FWHM also depends on the ratio of NA, mentioned above. Maximum increase in FWHM of axial response is about 5%.
منابع مشابه
Improvement of detected intensity in confocal microscopy by using reflecting optical system
In confocal microscopy, the level of the detected intensity is low, which reduces the contrast of the images. We propose a reflecting optical system to improve the detected intensity. The result of the optimal design is presented and the performance of the resulting reflecting optical system is evaluated. A numerical simulation of the effect of the reflecting optical system on the total system ...
متن کاملCharacterization of high-Q optical microcavities using confocal microscopy.
Confocal microscopy was initially developed to image complex circuits and material defects. Previous imaging studies yielded only qualitative data about the location and number of defects. In the present study, this noninvasive method is used to obtain quantitative information about the Q factor of an optical resonant cavity. Because the intensity of the fluorescent signal measures the number o...
متن کاملAn Approach for Characterizing and Comparing Hyperspectral Microscopy Systems
Hyperspectral imaging and analysis approaches offer accurate detection and quantification of fluorescently-labeled proteins and cells in highly autofluorescent tissues. However, selecting optimum acquisition settings for hyperspectral imaging is often a daunting task. In this study, we compared two hyperspectral systems-a widefield system with acoustic optical tunable filter (AOTF) and charge c...
متن کاملComposite au nanostructures for fluorescence studies in visible light.
We present results from composite plasmonic nanostructures designed to achieve the cascaded enhancement of electromagnetic fields at optical frequencies. Our structures comprise a small metallic nanodisc suspended above a larger disk. We probe the optical properties of these structures by coating them with a layer of a visible-light fluorophore and observing fluorescence signals with the help o...
متن کاملTrue confocal resonant scanning: a better solution for high-speed multifluorescence optical sectioning
Confocal imaging and high-speed solutions Confocal microscopy is a method for the recording of optical sections in which only in-focus signal is allowed to reach the detection system. True optical sectioning can create sections as thin as 0.2 μm (depending on wavelength, aperture diameter and incident light method). Typical sectioning ranges from 0.5 to 1 μm. A precondition for optical sectioni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002