Purification and characterization of different molecular forms of prostate-specific antigen in human seminal fluid.

نویسندگان

  • W M Zhang
  • J Leinonen
  • N Kalkkinen
  • B Dowell
  • U H Stenman
چکیده

We have developed a new procedure for purifying prostate-specific antigen (PSA) from human seminal fluid. The method is based on ammonium sulfate precipitation, hydrophobic interaction chromatography, gel filtration, and anion-exchange chromatography. It can be completed within 2 days with a recovery of intact PSA of 30%. By anion-exchange chromatography, five isoforms of PSA (A, B, C, D, and E) can be separated. The major form (PSA-B) consists of the intact enzyme, as shown by the occurrence of only one band of 33 kDa in sodium dodecyl sulfate-polyacrylamide gel electrophoresis under reducing or nonreducing conditions, and by amino acid sequencing, which reveals only one amino-terminal sequence corresponding to the reported amino-terminal sequence of intact PSA. The specific absorbance of 1 g/L PSA-B at 280 nm was 1.61, and 80% of the PSA-B formed a complex with alpha 1-antichymotrypsin, indicating that it is enzymatically active. Three cleaved forms of PSA with different nicking sites and low enzymatic activity were separated from intact PSA by ion-exchange chromatography. In addition, we isolated a glycosylation variant, PSA-A, which showed a higher isoelectric point (pI = 7.2) than PSA-B (pI = 6.9) but similar enzymatic activity; this form accounts for 5-10% of total PSA. After treatment with sialidase, PSA-A and B had the same isoelectric point value (pI = 7.7).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simplified and Reproducible Two-Step Method for the Purification of Prostate-Specific Antigen

Prostate-specific antigen (PSA) was purified to homogeneity from human seminal plasma by ion-exchange chromatography on a CM-Sephadex C-50 and by gel filtration on a Sephacryl S-200 column. A single 33-kDa protein band appeared in SDS-PAGE. High pressure liquid chromatography (HPLC) of the purified protein produced a single peak, while isoelectric focusing demonstrated the presence of five diff...

متن کامل

Molecular Form Differences Between Prostate-Specific Antigen (PSA) Standards Create Quantitative Discordances in PSA ELISA Measurements

The prostate-specific antigen (PSA) assays currently employed for the detection of prostate cancer (PCa) lack the specificity needed to differentiate PCa from benign prostatic hyperplasia and have high false positive rates. The PSA calibrants used to create calibration curves in these assays are typically purified from seminal plasma and contain many molecular forms (intact PSA and cleaved subf...

متن کامل

Concomitant purification of prostatic carcinoma tumor markers from human seminal fluid under nondenaturing conditions.

We report a protocol for concomitant purification to homogeneity of both prostatic acid phosphatase [orthophosphoric-monoester phosphohydrolase (acid optimum), EC 3.1.3.2] and prostate-specific antigen, from human seminal fluid. The method requires only two chromatographic steps: passage through an Affigel-Blue column and gel filtration HPLC. This is a fast, efficient procedure for purification...

متن کامل

Preparation of an artificial matrix to replace human standards of prostate specific antigen IRMA assay kit [Persian]

  Introduction: Prostate specific antigen (PSA) is one of the most sensitive markers for diagnosis of prostate cancer. Immunoradiometric kit (IRMA) is a common and sensitive method for determination of PSA in clinical laboratories. This kit has four major components: solid phase coated with monocolonal antibody, pair antibody labelled with I-125, series of standards i...

متن کامل

Preparation of prostate specific antigen standards for immunoradiometric assay

Background: Immunoradiometric assay is one of the most common and precise methods for determination of prostate specific antigen (PSA) in clinical laboratories. Usual use of human serum in routine assays has many disadvantages such as easy contamination and precipitation, instability and unavailability. Thus in order to avoid these problems the artificial matrix was used which acts sim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 1995