On the Application of Pmu Measurements to System Stability Analysis

نویسندگان

  • JIANGMENG ZHANG
  • Alejandro D. Domínguez-García
  • Alejandro D. Domínguez
  • Peter W. Sauer
چکیده

This thesis proposes a method to analyze power system stability by utilizing PMU measurements. As the current power system is operated close to its limits, stability is of high concern for both operators and customers. The implementation of phasor measurement units across the power system allows for accurate and fast stability monitoring and analysis. To address the application of PMU measurements to stability monitoring, we propose the use of circuit equivalent ideas for both voltage and angle stability. This method is applicable for on-line steady-state stability assessment, without knowing the system topology. For voltage stability, parameter estimation methods are investigated to address the tradeo between accuracy and computational speed. For angle stability, a modi ed model is presented to re ect the fact that the main change of the system occurs inside the equivalent system. Next, by taking advantage of PMU high measuring frequency, which provides a high resolution to monitor the systems, a frequency domain analysis based method is proposed to estimate the system equivalent inertia, which enables further dynamic stability analysis. The methods are illustrated with several simulated and real case studies. These algorithms are identi ed as e ective and simple methods to analyze system stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal PMU Placement Considering with HVDC Links and Their Voltage Stability Requirements

In wide area measurement systems, PMUs are the main component measuring real time synchronized data from different buses. Installation of PMUs at all buses is a primary way to provide full observability of the power network. However, it is not practical in real networks due to the relatively expensive cost of PMUs and other technical limitations. Optimal PMU Placement (OPP) is an optimization p...

متن کامل

A Nonlinear Voltage Stability Index based on Vector Analysis Method and Measurements of Active and Reactive Powers of Power System

This paper proposes a new voltage stability assessment method based on vector analysis method. This index extraction process relies on measurements of active and reactive powers from connected buses to the generator buses. Therefore, a limit for beginning of voltage collapse is determined based on the maximum power transfer theory. On the other hand, when the system requires load shedding, a ne...

متن کامل

Observability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies

Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conve...

متن کامل

Multi-Area State Estimation Based on PMU Measurements in Distribution Networks

State estimation in the energy management center of active distribution networks has attracted many attentions. Considering an increase in complexity and real-time management of active distribution networks and knowing the network information at each time instant are necessary. This article presents a two-step multi-area state estimation method in balanced active distribution networks. The prop...

متن کامل

Online Inertia Constant and Thévenin Equivalent Estimation Using PMU Data

In this paper a new algorithm based on phasor measurements for estimating the Thévenin Equivalent (TE) and system inertia constant is proposed. The method estimates the network TE seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at Phasor Data Concentrator (PDC) center. It is shown that the parameters of the TE could be estimated at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012