Parameter study of self-absorption effects in Total Reflection X-ray Fluorescence–X-ray Absorption Near Edge Structure analysis of arsenic☆
نویسندگان
چکیده
منابع مشابه
Grazing exit versus grazing incidence geometry for x-ray absorption near edge structure analysis of arsenic traces
In the presented study the grazing exit x-ray fluorescence was tested for its applicability to x-ray absorption near edge structure analysis of arsenic in droplet samples. The experimental results have been compared to the findings of former analyses of the same samples using a grazing incidence GI setup to compare the performance of both geometries. Furthermore, the investigations were accompl...
متن کاملEvaluation of X-Ray Absorption by Ointment Containing Bismuth Oxide Nanoparticles in Radiology Staff
Introduction: The effects of X-rays on carcinogens have been proven in recent years. Today, lead is used in many devices such as lead covers, thyroid protectors to protect the body against x-rays. But this equipment contains many disadvantages such as, Toxicity, High weight and Lack of flexibility. Today, newer methods, such as semi-solid skin care products (cream, ointment), a...
متن کاملInfluence of the Sample Morphology on Total Reflection X-ray Fluorescence Analysis
Total Reflection X-ray Fluorescence Analysis (TXRF) is a method for qualitative and quantitative analysis of trace elements. In general TXRF is known to allow for linear calibration typically using an internal standard for quantification. For small sample amounts (low ng region) the thin film approximation is valid neglecting absorption effects of the exciting and the detected radiation. Howeve...
متن کاملSynchrotron radiation-induced total reflection X-ray fluorescence analysis
Synchrotron radiation-induced total reflection X-ray fluorescence (SR-TXRF) analysis is a high sensitive analytical technique that offers limits of detection in the femtogram range for most elements. Besides the analytical aspect, SR-TXRF is mainly used in combination with angle-dependent measurements and/or X-ray absorption near-edge structure (XANES) spectroscopy to gain additional informatio...
متن کاملNew Correction Procedure for X-ray Spectroscopic Fluorescence Data: Simulations and Experiment
X-ray fluorescence spectroscopy is a widely used method for determining the electronic configuration and local structure of dilute species with high sensitivity. In the dilute limit, and for thin films, the X-ray fluorescence signal is directly proportional to the atomic sub-shell absorption coefficient. However, for concentrated samples, the well-documented self-absorption effect often leads t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008