Assessing the measurement of airway resistance by the interrupter technique.

نویسندگان

  • Yolanda Zuriarrain Reyna
  • Alejandro López Neyra
  • Verónica Sanz Santiago
  • Esmeralda Almería Gil
  • José Ramón Villa Asensi
چکیده

INTRODUCTION Pulmonary function tests allow an objective assessment of the degree of bronchial obstruction in collaborative subjects. The measurement of airway resistance using passive methods is very helpful in non-collaborative subjects. The objective of this study was to assess the applicability of measuring airway resistance by the interrupter technique (Rint) in pediatric subjects, determining its reproducibility, reliability and accuracy versus other techniques to measure airway resistance. MATERIAL AND METHODS Cross-sectional study in healthy children and in children with an obstructive airway disease, all aged 2-18 years old. The Rint was measured using a portable device and results were compared to airway resistance measured by oscillometry and plethysmography. The reproducibility of measurements and the infuence of the different outcome measures (use of mask or mouthpiece, cheek support, or nose clip) were assessed. RESULTS Valid measurements were obtained in 82.6% of 460 children (47.6% younger than 7 years old). Reproducibility was very good (ICC= 0.9412; p <0.00001), and no differences were found among the measurements obtained at separate time intervals (0.75 ± 0.3 versus 0.74 ± 0.28; p= 0.435). None of the factors indicated before had an effect on the reproducibility of measurements. Resistance values obtained by plethysmography and oscillometry were higher than those obtained using the Rint, with a positive correlation between them. The higher the degree of airway obstruction, the worse the correlation with plethysmography. CONCLUSIONS The Rint measurement is a plausible and reproducible technique, and has an adequate correlation with the resistance measurements obtained using oscillometry or plethysmography, thus making it useful for non-collaborative patients. In patients with airway obstruction, this technique could underestimate resistance, so it would be a hurdle to use it to follow-up subjects with a moderate to severe obstructive disease or in bronchial challenge tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A systematic review of lung function testing in asthmatic young children.

Asthma diagnosis is difficult in young children being mainly based on clinical signs and parents' history, which is sometimes difficult to obtain. Lung function testing may improve asthma diagnosis by objectively assessing its main features, airway obstruction, spontaneously reversible or after use of a bronchodilator drug, ventilation inhomogeneity during an acute bronchoconstriction and airwa...

متن کامل

A portable device based on the interrupter technique to measure bronchodilator response in schoolchildren.

A new device for measuring airway resistance following brief airflow interruption (Microlab 4000; Micromedical Ltd, UK) was evaluated in 25 asthmatic school children in comparison with well-established methods. Airway resistance was measured during brief airflow interruption (Rint), before and after administration of salbutamol 200 micrograms by metered-dose inhaler, and in the spirometric para...

متن کامل

Comparison of resistance measured by the interrupter technique and by passive mechanics in sedated infants.

Airways resistance measured by the interrupter technique (Rint) requires little patient cooperation and has been successfully used in young children, but little studied in infants. The authors aimed to evaluate the measurement of Rint in infants, using a commercially available device (the MicroRint), by comparing it with an established technique to measure respiratory resistance: the single bre...

متن کامل

Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting.

This study describes the feasibility, repeatability, and interrater reliability of the measurement of airway resistance by the interrupter technique (Rint) in children 2-5 yrs of age, and examines whether reversibility to bronchodilator can be demonstrated in wheezy children. The mean of six Rint values was taken as a measurement. If subjects could complete one measurement and then a second 15 ...

متن کامل

Interrupter airway and tissue resistance: errors caused by valve properties and respiratory system compliance.

The interrupter technique is used to determine airway and tissue resistance. Their accuracy is influenced by the technical properties of the interrupter device and the compliance of the respiratory system. We investigated the influence of valve characteristics and respiratory system compliance on the accuracy of determining airway and tissue resistance by means of a computer simulation. With de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos argentinos de pediatria

دوره 111 6  شماره 

صفحات  -

تاریخ انتشار 2013