Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output.

نویسندگان

  • C Schmidt
  • G Theilmeier
  • H Van Aken
  • P Korsmeier
  • S P Wirtz
  • E Berendes
  • A Hoffmeier
  • A Meissner
چکیده

BACKGROUND Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophageal Doppler echocardiographic quantification of CO (TOE-CO) has emerged as a reliable method, the purpose of this study was to determine the limits of agreement between CO estimations using EV (EV-CO) and TOE-CO. METHODS Standard ECG electrodes were used for non-invasive EV-CO measurements. These were placed on 37 patients scheduled for coronary artery surgery necessitating transoesophageal echocardiography monitoring. Simultaneous EV-CO and TOE-CO measurements were recorded after induction of anaesthesia. EV-CO was calculated using the Bernstein-Osypka equation. TOE-CO was measured across the aortic valve using continuous-wave Doppler echocardiography and a triangular orifice model. RESULTS A significant high correlation was found between the TOE-CO and the EV-CO measurements (r2=0.86). Data were related linearly. The slope of the line (1.10 (se 0.07)) was not significantly different from unity, and the point at which it intersected the ordinate (-0.46 (0.32) litre min(-1)) was not significantly different from zero. Bland-Altman analysis revealed a bias of 0.18 litre min(-1) with narrow limits of agreement (-0.99 to 1.36 litre min(-1)). CONCLUSIONS The agreement between EV-CO and TOE-CO is clinically acceptable, and these two techniques can be used interchangeably.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac outputy

Background. Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophagea...

متن کامل

Transoesophageal Echocardiography for Monitoring Liver Surgery: Data from a Pilot Study

A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, r...

متن کامل

Non-Invasive Cardiac Output Measurement in Low and Very Low Birth Weight Infants: A Method Comparison

BACKGROUND Cardiac output (CO) measurement in low (LBW) and very low (VLBW) birth weight infants is difficult. Hitherto, sporadical transthoracic echocardiography (TTE) is the only non-invasive measurement method. Electrical velocimetry (EV) has been evaluated as an alternative in normal weight newborns. OBJECTIVES The study was designed to evaluate if EV could be interchangeable with TTE eve...

متن کامل

قلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی

 Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...

متن کامل

Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.

BACKGROUND AND OBJECTIVE During off-pump coronary bypass grafting, surgical manipulation and dislocation of the heart may cause cardiovascular instability. Monitoring of cardiac output facilitates intraoperative haemodynamic management but pulmonary artery catheters are often considered too invasive. Pulse contour analysis and transoesophageal echocardiography could serve as alternatives, but t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 95 5  شماره 

صفحات  -

تاریخ انتشار 2005