SU-E-J-43: Autotuning Imaging Parameters in X-Ray Fluoroscopic Tracking for Dose Savings.

نویسندگان

  • S Siddique
  • E Fiume
  • D Jaffray
چکیده

PURPOSE In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precision threshold. METHOD AND MATERIALS An acrylic sphere (1.6mm in diameter) was imaged at tube currents ranging from 0.5 mA to 0.9mA (1s) at a fixed energy of 50kVp. The images were acquired on a Varian Paxscan 4030A (2048×1536 pixels, 1100 mm source-to-axis distance, 1570 mm source-to-detector distance). A state feedback metric (tr(C)) based on the current object position was computed and plotted as afunction of the tube current. Next, the sphere was tracked using a particle filter with a bowtie filter (4.3-764mm thickness, Al) in the background. The tr(C) was used a by a PID controller to modulate the tube current in order to maintain a specified precision as the sphere traversed regions of varying thickness corresponding to the bowtie filter. RESULT Comparison of thefeedback framework with a similar system employing fixed exposurereveals a dose savings of up to 43% when using an operating uncertainty of 194 mm2 . CONCLUSION This work presents a relation between tr(C) and thetube current which can be leveraged to reduce imaging dose to patients and staff.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Average Glandular Dose in Mammography for Rh-Rh Mammogram Using Sobol-Wu Parameters in FORTRAN Code

Introduction: To write a computational program to calculate the average glandular dose in Mammography with Rh-Rh target-filter and also use it as an accurate and fast method of dose calculation founder different situations. Materials and Methods: In this research, the Sobol-Wu parameters are used to write a FORTRAN code for glandular dose calculation in Rh-Rh target-filter mammograms. The code ...

متن کامل

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

X-ray fluoroscopy is widely used for image guidance during cardiac intervention. However, radiation dose in these procedures can be high, and this is a significant concern, particularly in pediatric applications. Pediatrics procedures are in general much more complex than those performed on adults and thus are on average four to eight times longer. Furthermore, children can undergo up to 10 flu...

متن کامل

Investigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

متن کامل

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Patient dose in routine X-ray examinations in Yazd state

Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part6  شماره 

صفحات  -

تاریخ انتشار 2012