Combined liquid chromatography/radioimmunoassay with improved specificity for serum digoxin.

نویسندگان

  • M H Gault
  • L Longerich
  • M Dawe
  • S C Vasdev
چکیده

This method for assaying digoxin in serum with improved specificity combines small-column extraction of serum, "high-performance" liquid chromatography, and RIA of the eluted fractions. Analytical recoveries of 1.0, 0.5, and 0.1 microgram/L standards were 95%, 93%, and 84%, respectively. The CVs for duplicates and replicates of sera with values of 0.5 to 1 microgram/L were 4 to 6%. Fifty-nine sera from 50 patients receiving digoxin were so studied. All digoxin metabolites appear to cross react with antibody to digoxin to various degrees. The most polar metabolites were quantitatively the most important, their average cross reactivity being 33%. For eight patients the value for digoxin by the present method was less than 60% of the RIA value. Sera from nine patients not taking digoxin but with falsely high digoxin values were also studied by the present method. The digoxin peak was well resolved from those for (a) digoxin metabolites (except dihydrodigoxin), (b) digitalis-like factors in neonates and in patients with renal failure or combined hepatic and renal failure, and (c) two cross reacting drugs and their metabolites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of radioimmunoassay for measurement of serum digoxin in digitalized patients using novel anti-digoxin antiserum.

There is an antiserum elicited by digoxin 3'-hemisuccinate-bovine serum albumin (BSA) conjugate possessing high specificity for digoxin. Our study focused on development of RIA using this novel antiserum for measurement of digoxin in serum from digitalized patients. The property of the new antiserum was investigated by RIA with digoxin 3'-hemisuccinyl-[3H]leucine. The separation of bound and fr...

متن کامل

Radioimmunoassay of ursodeoxycholic acid in serum.

A sensitivie and specific radioimmunoassay for the measurement of serum ursodeoxycholic acid has been developed. Ursodeoxycholic acid bound to bovine serum albumin was used as an antigen, and antiserum to this antigen was raised in the rabbit. [11, 12-3h2]Ursodeoxycholic acid was used as the radioactive tracer, and the radioimmunoassay was carried out by the method of Simmonds et al. (1973. Gas...

متن کامل

OPEN ACCESS Jacobs Journal of Nanomedicine and Nanotechnology Establishment of a Highly Specific Enzyme Immunoassay for Digoxin in Human Serum

We previously developed a radioimmunoassay for digoxin using an antiserum raised against digoxin 3’-hemisuccinate -bovine serum albumin. In the present study, we aimed to establish an enzyme immunoassay (EIA) for measuring serum digoxin level in patients, using digoxin 3’-hemisuccinate-β-D-galactosidase as an enzyme-labeled antigen. The developed enzyme immunoassay showed a quantification range...

متن کامل

Endogenous digoxin-like immunoreactive factors eliminated from serum samples by hydrophobic silica-gel extraction and enzyme immunoassay.

Elimination of endogenous digoxin-like immunoreactive factors (DLIF) that interfere with accurate measurement of digoxin requires use of a highly specific anti-digoxin antibody, or that DLIF be separated from digoxin before immunoassay. Several commercial digoxin-assay kits include a step for separating serum proteins and other substances from digoxin before immunoassay. We tested six different...

متن کامل

Radioimmunoassay Measurement of Serum Cardiac Glycoside Levels: Using Pharmacologic Principles to Solve Crossreactivity Problems

Laboratories performing analyses for serum cardiac glycosides are sometimes faced with the problem of distinguishing between digoxin and digitoxin in a specimen. The antibodies to the cardiac glycosides supplied with radioimmunoassay kits for these drugs have some measurable degree of cross reactivity. Therapeutic levels of digitoxin are approximately ten times greater than those of digoxin, an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 8  شماره 

صفحات  -