Minimax correlation between a line segment and a beamlet

نویسنده

  • Xiaoming Huo
چکیده

The minimax correlation between a line segment and a beamlet is proved to be 2 : The result is useful for design of efficient line-segment detectors with noisy data. r 2005 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exact lower bound for proportion of maximally embedded beamlet

We prove that the maximal inscribed beamlet is at least 1/7 of an arbitrary line segment (i.e., beam). The implication of this result is addressed.

متن کامل

Beamlets and Multiscale Image Analysis

We describe a framework for multiscale image analysis in which line segments play a role analogous to the role played by points in wavelet analysis. The framework has five key components. The beamlet dictionary is a dyadicallyorganized collection of line segments, occupying a range of dyadic locations and scales, and occurring at a range of orientations. The beamlet transform of an image f(x, y...

متن کامل

Applications of Beamlets to Detection and Extraction of Lines, Curves and Objects in Very Noisy Images

Beamlets are a special dyadically organized collection of line segments, exhibiting a range of lengths, positions and orientations. This collection is relatively compact: there are O(n log2(n)) beamlets, compared to O(n) line segments. This collection is relatively expressive: up to a certain tolerance, it does not take more than O(log2(n)) beamlets to approximate a single line segment. Because...

متن کامل

Iterative regularization in intensity-modulated radiation therapy optimization.

A common way to solve intensity-modulated radiation therapy (IMRT) optimization problems is to use a beamlet-based approach. The approach is usually employed in a three-step manner: first a beamlet-weight optimization problem is solved, then the fluence profiles are converted into step-and-shoot segments, and finally postoptimization of the segment weights is performed. A drawback of beamlet-ba...

متن کامل

بررسی پیش‌آگهی افت قطعه PR و ارتباط آن با عوارض احتمالی در بیماران با تشخیص انفارکتوس میوکارد

Background & Aims: The aim of this study was to determine the clinical importance of PR segment depression after MI in prognosis of patients with acute myocardial infarction. Materials & Methods: This descriptive analysis study was conducted on 413 patients (283 patients were men and 130 women). The first ECG of all myocardial infarction patients was checked to determine PR segment ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005