Susceptibility‐induced distortion correction in hyperpolarized echo planar imaging

نویسندگان

  • Jack J Miller
  • Angus Z Lau
  • Damian J Tyler
چکیده

PURPOSE Echo planar imaging is an attractive rapid imaging readout that can image hyperpolarized compounds in vivo. By alternating the sign of the phase encoding gradient waveform, spatial offsets arising from uncertain frequency shifts can be determined. We show here that blip-reversed echo planar imaging can also be used to correct for susceptibility and B0 inhomogeneity effects that would otherwise produce image-domain distortion in the heart. METHODS Previously acquired blip-reversed cardiac 3D-Spectral-Spatial echo planar imaging volumetric timecourses of hyperpolarized [1-13 C]pyruvate were distortion corrected by a deformation field estimated by reconstructing signal-to-noise ratio (SNR)-weighted progressively subsampled temporally summed images of each metabolite. RESULTS Reconstructing blip-reversed data as proposed produced volumetric timecourses that overlaid with proton reference images more consistently than without such corrections. CONCLUSION The method proposed may form an attractive method to correct for image-domain distortions in hyperpolarized echo planar imaging experiments. Magn Reson Med 79:2135-2141, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

Geometric distortion correction in echo volumar imaging

Introduction: Echo volumar imaging (EVI) is a 3D extension of echo-planar imaging (EPI) that allows data from an entire volume to be acquired following a single excitation. However, only a few studies to date have applied EVI to functional MRI (fMRI) due to its high sensitivity to field-inhomogeneity induced distortions. In this study, we extend two EPI distortion correction techniques to EVI: ...

متن کامل

Correction of B0 susceptibility induced distortion in diffusion-weighted images using large-deformation diffeomorphic metric mapping.

Geometric distortion caused by B0 inhomogeneity is one of the most important problems for diffusion-weighted images (DWI) using single-shot, echo planar imaging (SS-EPI). In this study, large-deformation, diffeomorphic metric mapping (LDDMM) algorithm has been tested for the correction of geometric distortion in diffusion tensor images (DTI). Based on data from nine normal subjects, the amount ...

متن کامل

Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging.

The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data is severely degraded in the presence of head motion. In addition, EPI is sensitive to susceptibility-induced geometric distortions. Head motion causes image shifts and associated field map changes that induce different geometric distortion at different time points. Conventio...

متن کامل

Combined Prospective Rigid-Body Motion Correction with Retrospective Non-Rigid Distortion Correction for EPI

Introduction: Prospective real-time motion correction, where the scan-plane orientation is dynamically updated to track with the subject's head during an MRI scan, is becoming increasingly popular (1-7). While these methods focus on compensating for bulk rigid-body motion, a secondary effect of head motion is non-rigid-body image distortion caused by changes in the effective shim within the bra...

متن کامل