An improved reconstruction procedure for the correction of local magnification effects in three-dimensional atom-probe

نویسندگان

  • F. De Geuser
  • W. Lefebvre
  • F. Danoix
  • F. Vurpillot
  • B. Forbord
  • D. Blavette
چکیده

A new 3DAP reconstruction procedure is proposed, which accounts for the evaporation field of a secondary phase. It applies the existing cluster selection softwares to identify the atoms of the second phase and subsequently an iterative algorithm to homogenise the volume laterally. This procedure, easily implementable on existing reconstruction software, has been applied successfully on simulated and real 3DAP analyses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improved reconstruction procedure for the correction of local magnification effects in 3DAP

A new 3DAP reconstruction procedure is proposed, which accounts for the evaporation field of a secondary phase. It applies the existing cluster selection softwares to identify the atoms of the second phase and subsequently an iterative algorithm to homogenise the volume laterally. This procedure, easily implementable on existing reconstruction software, has been applied successfully on simulate...

متن کامل

Local Field Correction Effect on Dicluster Stopping Power in a Strongly Coupled Two-Dimensional Electron Gas System

We calculate the stopping power for heavy-ion diclusters moving in a strongly coupled two-dimensional electron gas system by using the local field corrected dielectric function at finite temperature. We obtain a parameterized local field correction factor based on a relation between the thermal compressibility and exchange-correlation energy in two-dimension. The interpolated parameter is deriv...

متن کامل

A Zigzag Theory with Local Shear Correction Factors for Semi-Analytical Bending Modal Analysis of Functionally Graded Viscoelastic Circular Sandwich Plates

Free bending vibration analysis of the functionally graded viscoelastic circular sandwich plates is accomplished in the present paper, for the first time. Furthermore, local shear corrections factors are presented that may consider simultaneous effects of the gradual variations of the material properties and the viscoelastic behaviors of the materials, for the first time. Moreover, in contrast ...

متن کامل

The Effect of Substitution of a Zn Atom in Cdn-1TenClusters (n=1-10)

In this research, structural and electronic properties of ZnCdn-1Ten clusters (n=1-10) have been studied by formalism of density functional theory and using the projector augmented wave within local density approximation. The structural properties (such as bond length/angle and coordination number), electronic and optical properties (such as binding energy, Kohn-Sham spect...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017