Effectiveness of remote monitoring in the management of syncope and palpitations.
نویسندگان
چکیده
AIMS Recently, the remote transmission of data detected by implantable loop recorders (ILRs) has become available. The aim of this study was to evaluate effectiveness and acceptance of remote monitoring in the clinical management of syncope and palpitations in patients with ILR. METHODS AND RESULTS Consecutive patients implanted with ILR (Reveal DX/XT Medtronic, Inc.) and followed up by means of remote monitoring (CareLink(®)) were included. The patients were requested to transmit the data stored in the ILR every week, via the CareLink system, or more frequently during the first period. Patient acceptance of ILR was evaluated by means of a questionnaire concerning physical and mental components. Forty-seven patients (27 males, average age 64 ± 19 years) were enrolled and followed up for 20 ± 13 weeks. Thirty-two patients (68%) had at least one ECG recording of a true relevant event. The mean time from ILR implantation to the first true relevant ECG was 28 ± 49 days, which was 71 ± 17 days less than in the clinical practice of 3-monthly in-office follow-up examinations. Thirty-eight patients (81%) had at least one false arrhythmic event, mainly false asystole and false fast ventricular tachycardia. In the absence of Carelink transmission, at least one episode of memory saturation of ILR would have occurred in 21 patients (45%) that would have limited the diagnostic yield. Patient compliance was good even though one-fifth had some minor psychological concern regarding the ILR implant. CareLink was well accepted and judged easy to use. CONCLUSION Remote monitoring enhances the diagnostic effectiveness of Reveal, limiting the risk of memory saturation due to the high number of false detections and reducing the time to diagnosis. Both ILR and CareLink were well accepted and well tolerated by the patients, as they were considered useful.
منابع مشابه
Effectiveness and safety of remote monitoring of patients with an implantable loop recorder.
INTRODUCTION AND OBJECTIVES Implantable loop recorders have proven efficacy in the study of patients with syncope and palpitations. Remote monitoring of patients with pacemakers and implantable cardioverter-defibrillators has been shown to be safe and effective. The purpose of this study was to analyze the safety and effectiveness of remote monitoring in patients with an implantable loop record...
متن کاملExternal prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study
AIMS SYNARR-Flash study (Monitoring of SYNcopes and/or sustained palpitations of suspected ARRhythmic origin) is an international, multicentre, observational, prospective trial designed to evaluate the role of external 4-week electrocardiogram (ECG) monitoring in clinical work-up of unexplained syncope and/or sustained palpitations of suspected arrhythmic origin. METHODS AND RESULTS Consecuti...
متن کاملEtiology of syncope in hospitalized patients
Background: Syncope is a common clinical problem which can be remarkably debilitating and associated with high health care costs. Syncope is a clinical syndrome with many potential causes. The aim of the study was to determine the etiologies of patients with syncope in the emergency department (ED) of a referral and general university hospital. Methods: One hundred sixty-five consecutive ...
متن کاملRemote sensing technology for mapping and monitoring vegetation cover (Case study: Semirom-Isfahan, Iran)
To determine the suitable indices for vegetation cover and production assessment based on the remote sensing data, simultaneous digital data with field data belonging to the spring rangeland of the Semirom-Isfahan province were analyzed. During two years of monitoring the annual, grass, forb, and shrub vegetation cover and the total production data from 86 were collected. The Global Positioning...
متن کاملRemote sensing technology for mapping and monitoring vegetation cover (Case study: Semirom-Isfahan, Iran)
To determine the suitable indices for vegetation cover and production assessment based on the remote sensing data, simultaneous digital data with field data belonging to the spring rangeland of the Semirom-Isfahan province were analyzed. During two years of monitoring the annual, grass, forb, and shrub vegetation cover and the total production data from 86 were collected. The Global Positioning...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 13 3 شماره
صفحات -