Comparison of anthropometric equations for estimation of total body water in peritoneal dialysis patients.

نویسندگان

  • Graham Woodrow
  • Brian Oldroyd
  • Antony Wright
  • W Andrew Coward
  • John G Truscott
  • John H Turney
  • Aleck M Brownjohn
  • Michael A Smith
چکیده

BACKGROUND Several formulae exist for estimating total body water (TBW). We aimed to assess their validity in peritoneal dialysis patients by comparison with TBW estimated by deuterium oxide dilution (TBW(D)). METHODS We compared the equations of Chertow (TBW(Cher)), Chumlea (TBW(Chum)), Hume and Weyers (TBW(HW)), Johansson (TBW(J)), Lee (TBW(L)), Watson (TBW(W)) and TBW as 58% of body weight (TBW(0.58Wt)) with TBW(D) in 31 peritoneal dialysis (PD) patients and 32 controls. Estimates were compared with TBW(D) using Bland and Altman comparison. Extracellular water (ECW) was also estimated by sodium bromide dilution. RESULTS In PD patients, mean TBW(D) was 35.04 (SD 7.84) l. Estimates were greater for TBW(Cher), TBW(Chum), TBW(HW), TBW(J) and TBW(0.58Wt). Mean TBW(L) and TBW(W) did not differ from TBW(D). Ninety-five percent limits of agreement (LOA) compared with TBW(D) (as a percentage of the mean) were similar for all of the different equations in PD patients (between +/-15.4 and +/-17.3%) except TBW(0.58Wt), which was far greater (+/-26.4%). In controls, mean TBW(D) was 37.03 (SD 6.63) l. Estimates were greater for TBW(Cher), TBW(Chum), TBW(HW), TBW(J) and TBW(0.58Wt). Mean TBW(L) and TBW(W) did not differ from TBW(D). Ninety-five percent LOA compared with TBW(D) (as a percentage of the mean) were similar for all equations in the controls, and closer than in PD patients (between +/-9.1 and +/-11.5%) except TBW(0.58Wt), which was again far greater than the other equations (+/-28.1%). TBW(HW) - TBW(D) correlated with mean TBW (r=-0.412, P<0.05 in PD and r=-0.383, P<0.05 in controls). TBW(W) - TBW(D) (r=-0.539, P<0.005) correlated with mean TBW in PD. TBW(0.58Wt) - TBW(D) correlated with body mass index (BMI) (r=0.624, P<0.0001 in PD and r=0.829, P<0.0001 in controls) and ECW/TBW (r=0.406, P<0.05 in PD and r=0.411, P<0.02 in controls). CONCLUSIONS Predictive equations were less accurate in PD than controls. TBW(0.58Wt) was most inaccurate, with systematic overestimation of TBW with increasing BMI and ECW/TBW. There were no differences in LOA with TBW(D) for the other equations within each group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Limitations in anthropometric calculations of total body water in patients on peritoneal dialysis.

Having an accurate estimation of total body water (TBW) is essential for the evaluation of dialysis efficacy in peritoneal dialysis (PD) patients. In this study, TBW volumes were measured by tritium dilution (TBW(THO)) in 165 PD patients and compared with TBW calculations according to the Watson formulas. An alternative anthropometric formula based on the present PD population was also develope...

متن کامل

Body composition evaluation in peritoneal dialysis patients using anthropometric formulas estimating body water.

In adult patients on peritoneal dialysis (PD), estimates of body water (V), fat-free mass (FFM), and body fat (BF) can be obtained by using anthropometric formulas for estimating V. Estimates of V, FFM, and BF can also be obtained by using reference (standard) methods in which V is evaluated by a standard dilution method. To test whether the estimates obtained by the various methods agree, we a...

متن کامل

Differences in clinical and laboratory data of peritoneal dialysis patients selected according to body mass index.

The aim of the present study was to compare parameters of dietary intake, nutritional status, dialysis adequacy, and laboratory data between continuous ambulatory peritoneal dialysis (CAPD) patients having a normal body mass index (BMI) and those having an increased BMI. Two groups were selected: BMI = 20-25 (group I, n = 29) and BMI = 25-30 (group II, n = 19). No difference in age or peritonea...

متن کامل

Lack of precision of indirect estimates of body water affects urea kinetic analysis in chronic peritoneal dialysis.

To test the precision of estimates of body water and urea clearance in peritoneal dialysis (PD), we compared, in 925 PD patients who underwent formal urea kinetics studies, estimates of V and Kt/V urea obtained by the use of the Watson, Hume, and Sahlgrenska anthropometric formulas and two novel formulas, one (Vcreat) computed using fat-free mass (FFM) estimated from creatinine kinetics as 0.73...

متن کامل

The effects of racial differences on body composition and total body water measured by multifrequency bioelectrical impedance analysis influence delivered Kt/V dialysis dosing.

INTRODUCTION Haemodialysis dosing is traditionally based on urea clearance (Kt/V). Aiming for the same Kt/V target, some racial groups have better survival. We investigated whether body composition differs with ethnicity and may lead to differences in Kt/V delivered. METHODS We compared total body water (TBW) measured by multifrequency bioelectrical impedance analysis (MF-BIA) that calculated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2003