Evaluation of transcutaneous bilirubinometer (DRAEGER JM 103) use in Zimbabwean newborn babies

نویسندگان

  • Gwendoline Lilly Tanyaradzwa Chimhini
  • Simbarashe Chimhuya
  • Vasco Chikwasha
چکیده

Background Acute Bilirubin Encephalopathy in the neonatal period is a major cause of permanent disability. Effective screening and surveillance are essential in the newborn period to enable timely management. Noninvasive transcutaneous bilirubin devices have been successfully used for screening in many settings. We evaluated the accuracy of the Draeger JM 103 (Medical Systems, USA) for estimating serum bilirubin in Zimbabwean newborns. Methods Paired transcutaneous (forehead and sternum) and serum bilirubin measurements were compared on 283 infants consecutively recruited between 01 August and 30 November 2015 at Harare Hospital Neonatal Unit. Using serum bilirubin as gold standard, Pearson Correlation Coefficient (r) was calculated for the two transcutaneous measurement sites. Linear regression plots of transcutaneous versus serum estimates were performed. Comparison was made between preterm and term babies. Specificity, sensitivity, positive predictive value and negative predictive value of the JM103 were calculated including ROC curves to assess the accuracy of the diagnostic tests. Results Fifty-five percent of the babies were male. Median gestational age was 38 weeks (range 28-42). One hundred and fifteen (41%) were preterm. Median postnatal age was 3 days (range 0-10). Serum bilirubin ranged 85-408 μmol/l, transcutaneous bilirubin sternum; 170-544 μmol/l and forehead; 119-510 μmol/l. Correlation between serum and transcutaneous bilirubin (sternum) was 0.77 and between serum and transcutaneous (forehead) was 0.72. Preterm babies correlation for sternum was 0.77 and forehead was 0.75. Term babies correlation for sternum was 0.76 and forehead was 0.70. The sensitivity for the sternum site was 76%, specificity 90%, Positive Predictive Value of 70 and Negative Predictive Value 92. Sensitivity for forehead site was 62%, specificity 95% with a Positive Predictive Value of 80 and Negative Predictive Value of 90. Bland-Altman plot of serum versus transcutaneous measurements showed agreement between the tests. The ROC curves showed that the accuracy of the two diagnostic tests were good with no significant difference between the two, p = 0.2954. Conclusion The study demonstrated a strong positive correlation for both sternum and forehead sites with serum bilirubin in this Zimbabwean population of African origin. However, the sternum is a better site for identifying babies with jaundice compared to forehead. The Draeger JM-103 can be used to screening for neonatal jaundice in this population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transcutaneous and total serum bilirubin measurement in Turkish newborns.

Severe neonatal hyperbilirubinemia can be prevented by screening for neonatal jaundice. Transcutaneous bilirubin (TcB) measurement is a noninvasive method for screening neonates. The aim of this study was to examine the correlation between TcB measurement (using the JM-103 bilirubinometer) and total serum bilirubin (TSB) measurement. To our knowledge, this is the first study evaluating the usef...

متن کامل

Evaluation of a point-of-care transcutaneous bilirubinometer in Chinese neonates at an accident and emergency department.

OBJECTIVE To evaluate the use of a point-of-care transcutaneous bilirubinometer, JM-103 Minolta, for estimation of the serum bilirubin level in the management of neonatal jaundice in term or near-term Chinese neonates. DESIGN Prospective correlation study. SETTING Accident and Emergency Department of a regional hospital in Hong Kong. PATIENTS All term or near-term Chinese neonates aged 3 ...

متن کامل

BiliCheck vs JM-103 in identifying neonates not at risk of hyperbilirubinaemia

BACKGROUND Transcutaneous bilirubinometry is widely used to predict hyperbilirubinemia by using several devices. The aim of this study was to compare the predictive ability of BiliCheck vs JM-103 in identifying neonates not at risk of significant hyperbilirubinemia, putting the data obtained with the two instruments on our transcutaneous bilirubin nomogram built with the BiliCheck. METHODS Tr...

متن کامل

Evaluation of a new transcutaneous bilirubinometer.

OBJECTIVE The objective of this study was to evaluate the Minolta/Hill-Rom Air-Shields Transcutaneous Jaundice Meter model JM-103. METHODS We studied a convenience sample of 849 newborns > or =35 weeks of gestation in 3 hospitals. These infants had total serum bilirubin (TSB) levels measured on clinical indication, and transcutaneous bilirubin (TcB) levels were obtained within 1 hour of the T...

متن کامل

Transcutaneous Bilirubin Nomogram for Healthy Term and Late Preterm Neonates in First 96 Hours of Life.

BACKGROUND To develop nomogram of Transcutaneous Bilirubin among healthy term and late-preterm neonates during first 96 hours of age. DESIGN Longitudinal observational study. SETTING Neonatal unit of a tertiary care Hospital of Central Gujarat, India. Participants 1075 healthy term and late preterm neonates (≥35weeks). INTERVENTION Six-hourly transcutaneous bilirubin was obtained from b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2018