High-resolution transparent x-ray beam location and imaging.
نویسندگان
چکیده
We present a high-resolution in situ imaging and localization method of energetic particle beams. Recording of the scattered radiation from a thin featureless foil, placed in the path of the beam, and taken with a pinhole or coded aperture camera arrangement magnifies beam movements at the sensor. At the same time, a magnified image of the beam is available with an exceptional signal-to-noise ratio. We show measurement results of the level of precision that can be achieved and compare them to theoretical limits based on the signal-to-noise levels.
منابع مشابه
On the resolution and linearity of lensless in situ X-ray beam diagnostics using pixelated sensors.
We present a theoretical model that describes the resolution and linearity of a novel transparent X-ray beam imaging and position measurement method. Using a pinhole or coded aperture camera with pixelated area sensors to image a small fraction of radiation scattered by a thin foil placed at oblique angles with respect to the beam, a very precise measurement of the beam position is made. We sho...
متن کاملDesign of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies
Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...
متن کاملAn accumulative x-ray streak camera with sub-600-fs temporal resolution and 50-fs timing jitter
Related Articles Compact x-ray microradiograph for in situ imaging of solidification processes: Bringing in situ x-ray micro-imaging from the synchrotron to the laboratory Rev. Sci. Instrum. 82, 105108 (2011) Simultaneous sample and spatial coherence characterisation using diffractive imaging Appl. Phys. Lett. 99, 154103 (2011) Heat transfer simulation and thermal measurements of microfabricate...
متن کاملCollimated superfine x-ray beam based x-ray luminescence computed tomography.
X-ray luminescence computed tomography (XLCT) is a hybrid imaging modality with the potential to achieve a spatial resolution up to several hundred micrometers for targets embedded in turbid media with a depth larger than several millimeters. In this paper, we report a high spatial resolution XLCT imaging system with a collimated superfine x-ray beam in imaging the deeply embedded targets. A co...
متن کاملConfocal soft X-ray scanning transmission microscopy: setup, alignment procedure and limitations
Zone-plate-based scanning transmission soft X-ray microspectroscopy (STXM) is a well established technique for high-contrast imaging of sufficiently transparent specimens (e.g. ultrathin biological tissues, polymer materials, archaeometric specimens or magnetic thin films) with spatial resolutions in the regime of 20 nm and high spectroscopic or chemical sensitivity. However, due to the relativ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2011