The Use of a Hydraulic Purifier for Conditioning of Phosphate Ester Hydraulic Fluids
نویسنده
چکیده
An improved procedure for controlling the acidity ofphosphate esters is described. In the presence of water phosphate esters undergo hydrolysis which increases the acidity of the jluid and eventually lea& to fluid degradation. Currently this problem is addressed through the use of acid adsorbing andor neutralizing agents such as Fuller's earth or activated alumina. Bese agents neutralize the acidic species formed in the hydrolysis reaction but do not remove water which is the cause of the problem. In contrast, the procedure described herein relies on water removal to prevent hydrolysk. Removal of water is accomplished with a spinning disc purifier which employs the vacuum dehydratiodmass transfer principle. In addition, the purlper is equipped with a 3 pm (,& 2 200 rated) filter for particulate removal. Results of studies at East and West coast power plants operated by two major utilities indicate that by maintaining low water and particulate content in the fluid, the purifier effectively reduced the rate of phosphate ester hydrolysis. These data therefore suggest that the service l f e of both thejluid and the neutralizing agent can be extended beyond the present two year period observed on average in the power generation industry. INTRODUCTION Phosphate esters are used in industrial hydraulic and lubricating applications where the use of petroleum based fluids would constitute a fire hazard. Typical applications include aircraft hydraulic systems, electrohydraulic turbine control (EHC) systems in power plants and hydraulic furnace door controls in aluminum smelting plants'-'. Phosphate esters exhibit excellent lubricating characteristics and decompose thermally into phosphoric acid which acts as a fire retardant. However, these fluids absorb water much more readily than their petroleum counterparts: water concentrations may be as 0.10 percent or higher'". The presence of water is undesirable because the fluid can decompose into acidic components. The quantity which measures the extent of phosphate ester decomposition is the total acid number or TAN. The TAN of the fluid is determined either from a potentiometric titration (ASTM D-664 method') or from a color-indicator titration (ASTM D-974 methodg) and is expressed in milligrams of potassium hydroxide required to neutralize one gram of fluid (mg KOWg fluid). To reduce the rate of decomposition, adsorbing and/or neutralizing agents (Fuller's earth or activated alumina) have been employed24*'0*11. The latter is often available in the form of a proprietary activated ahmindzeolite composite. The use of these agents often presents several drawbacks of its own. Variability in composition of Fuller's earth leads to differences in activity;
منابع مشابه
The high-temperature degradation of hydraulic oils and fluids©
The rapid darkening of hydraulic oils and fluids in use has occasionally been reported. This paper summarizes the past investigations into this phenomenon, which have largely focused on the compression of air bubbles in mineral hydraulic oil. The process leads to a form of high temperature degradation known as dieseling and the probable formation of sub-micron carbonaceous particles. The import...
متن کاملEffect of Combining Hydraulic and Phosphate Bonds on Alumina-Spinel Low Cement Castables
A basic alumina-spinel low cement castable (LCC) composed of sintered bauxite, reactive alumina, calcined alumina, calcined magnesia, microsilica, and high alumina refractory cement was prepared (castable A) to which 5% sodium hexa-meta phosphate was later added (castable B) to prepare samples for heat treatment at 110ºC, 900ºC, and 1400ºC. Bulk Density (BD), Apparent Porosity (AP), and Cold Cr...
متن کاملAnalysis of Acid Number in Phosphate Esters by FTIR Spectroscopy
In the nuclear power sector, electricity is generated from the steam generated by large turbines which are highly reliant on efficient electro-hydraulic turbine speed control systems (EHC). These systems offer a wide range of control options and operate at pressures of over 1000 psi to ensure rapid hydraulic response. At these pressures the potential for leaks of hydraulic fluid is greater as i...
متن کاملAn experimental study on hydraulic behavior of free-surface radial flow in coarse-grained porous media
The equations of fluids in porous media are very useful in designing the rockfill and diversion dams, gabions, breakwaters and ground water reserves. Researches have been showed that the Forchheimer equation is not sufficient for the analysis of hydraulic behavior of free-surface radial flows; because, in these flows, in addition to the hydraulic gradient and velocity, the variable of radius is...
متن کاملStatistical Review of Major Standpoints in Hydraulic Transient-Based Leak Detection
Today, pipe systems are the most common facilities to convey various fluids from one place to another. In such facilities faults like leaks lead to advert consequences such as economic losses and social health threats. The fact that early detection of leaks can play a prominent role in reducing the amount of these undesired impacts has absorbed noticeable attention from researchers to this fiel...
متن کامل