Unusual case of a graphite foreign body in the anterior chamber

نویسندگان

  • Anika Amritanand
  • Sheeja S. John
  • Swetha S. Philip
  • Deepa John
  • Sarada David
چکیده

Retained intraocular graphite foreign bodies are uncommon. Although they are generally inert, they have been reported to cause severe inflammatory reaction and progressive damage to intraocular structures. We report a case of a six-year-old girl with a retained intraocular graphite pencil lead foreign body in the anterior chamber of the eye and discuss the various considerations in the management of such cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case of Retained Graphite Anterior Chamber Foreign Body Masquerading as Stromal Keratitis

We report a case of a retained graphite anterior chamber foreign body that was masquerading as stromal keratitis. A 28-year-old male visited with complaints of visual disturbance and hyperemia in his right eye for four weeks. On initial examination, he presented with a stromal edema involving the inferior half of the cornea, epithelial microcysts, and moderate chamber inflammation. Suspecting h...

متن کامل

Management of an Unusual Tracheoesophageal Party Wall Foreign Body

Introduction: Penetration injury to the neck constitutes 5–10% of all trauma cases. Penetration of a foreign body into the trachea with subsequent impaction into the tracheoesophageal party wall is extremely rare. We present a patient with an unusual penetrating injury of the neck caused by a metallic foreign body embedded into the tracheoesophageal party wall, and its management.   Case Repor...

متن کامل

Unusual presentation of an abdominal foreign body: A case report

Background: Insertion of rectal foreign bodies intentionally or unintentionally is not unusual. Case presentation: A 19-years-old unmarried male was admitted to our hospital due to a lump of left lower quadrant of abdomen. He denied sexual assault .The abdomen was soft on physical examination. Abdominal x-ray and CT scan showed a foreign body in lower abdomen and pelvis. The patient was oper...

متن کامل

Suspected Endothelial Pencil Graphite Deposition

A 14-year-old male patient had an ocular trauma with a pencil. Biomicroscopic examination revealed a broken part of pencil into the cornea. Foreign body removal and corneal wound closure were performed in the same day. After corneal repair, there was a grade 4+ anterior chamber reaction just like in preoperative examination. Dilated examination showed a very small piece broken tip of pencil on ...

متن کامل

Superglue self-insertion an unusual case of foreign body into the male urethra – A case report

Background: Foreign body insertion in the urethra and bladder are relatively rare. These patients usually insert foreign body in urethra for eroticism, inquisitiveness, or as a consequence of disinhibited or disturbed behavior. Case presentation: Herein, we report a case of 41-year-old man presented with weak stream and suprapubic pain. Due to incontinence, he instilled superglue into his uret...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2011