The linear-quadratic model is an appropriate methodology for determining isoeffective doses at large doses per fraction.
نویسنده
چکیده
The tool most commonly used for quantitative predictions of dose/fractionation dependencies in radiotherapy is the mechanistically based linear-quadratic (LQ) model. The LQ formalism is now almost universally used for calculating radiotherapeutic isoeffect doses for different fractionation/protraction schemes. In summary, the LQ model has the following useful properties for predicting isoeffect doses: (1) it is a mechanistic, biologically based model; (2) it has sufficiently few parameters to be practical; (3) most other mechanistic models of cell killing predict the same fractionation dependencies as does the LQ model; (4) it has well-documented predictive properties for fractionation/dose-rate effects in the laboratory; and (5) it is reasonably well validated, experimentally and theoretically, up to about 10 Gy/fraction and would be reasonable for use up to about 18 Gy per fraction. To date, there is no evidence of problems when the LQ model has been applied in the clinic.
منابع مشابه
Use of the LQ model with large fraction sizes results in underestimation of isoeffect doses.
PURPOSE To test the appropriateness of the linear-quadratic (LQ) model to describe survival of jejunal crypt clonogens after split doses with variable (small 1-6 Gy, large 8-13 Gy) first dose, as a model of its appropriateness for both small and large fraction sizes. METHODS C3Hf/KamLaw mice were exposed to whole body irradiation using 300 kVp X-rays at a dose rate of 1.84 Gy/min, and the num...
متن کاملThe linear-quadratic model is inappropriate to model high dose per fraction effects in radiosurgery.
The linear-quadratic (LQ) model is widely used to model the effect of total dose and dose per fraction in conventionally fractionated radiotherapy. Much of the data used to generate the model are obtained in vitro at doses well below those used in radiosurgery. Clinically, the LQ model often underestimates tumor control observed at radiosurgical doses. The underlying mechanisms implied by the L...
متن کاملStraightening Beta: Overdispersion of Lethal Chromosome Aberrations following Radiotherapeutic Doses Leads to Terminal Linearity in the Alpha–Beta Model
Recent technological advances allow precise radiation delivery to tumor targets. As opposed to more conventional radiotherapy-where multiple small fractions are given-in some cases, the preferred course of treatment may involve only a few (or even one) large dose(s) per fraction. Under these conditions, the choice of appropriate radiobiological model complicates the tasks of predicting radiothe...
متن کاملBiological Dose Assessment by Chemical Induction of Premature Chromosome Condensation
Dose assessment of radiation victims is a key element in medical management of radiation accidents. At high radiation doses (> 6 Gy), dicentric assay lose its efficiency and premature chromosome condensation (PCC) assay was proposed to overcome the restrictions of dicentric assay. It was shown that PCC ring is more suitable and simpler than dicentric for biodosimetry in high radiation doses. In...
متن کاملInvestigating the Implications of a Variable RBE on Proton Dose Fractionation Across a Clinical Pencil Beam Scanned Spread-Out Bragg Peak.
PURPOSE To investigate the clinical implications of a variable relative biological effectiveness (RBE) on proton dose fractionation. Using acute exposures, the current clinical adoption of a generic, constant cell killing RBE has been shown to underestimate the effect of the sharp increase in linear energy transfer (LET) in the distal regions of the spread-out Bragg peak (SOBP). However, experi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Seminars in radiation oncology
دوره 18 4 شماره
صفحات -
تاریخ انتشار 2008