Simultaneous Exposure Using 532 and 860 nm lasers for visible lesion thresholds in the rhesus retina.

نویسندگان

  • William Roach
  • Robert Thomas
  • Gavin Buffington
  • Garrett Polhamus
  • John Notabartolo
  • Cheryl DiCarlo
  • Kevin Stockton
  • David Stolarski
  • Kurt Schuster
  • Val Carothers
  • Benjamin Rockwell
  • Clarence Cain
چکیده

The growth of commercially available, simultaneous multi-wavelength laser systems has increased the likelihood of possible ocular hazard. For example, many systems utilize frequency multiplying methods to produce combinations of visible, near-infrared, and ultraviolet wavelengths. Unfortunately, very little data exists to substantiate the current methods for estimating hazards from simultaneous lasing. To properly assess the retinal hazards from these wavelengths, the retinal effects of 10-s laser irradiation from 532 and 860 nm were determined in non-human primates for four different relative dosage combinations of these wavelengths. This pair of wavelengths represents the typical problem of a visible-wavelength laser combined with an in-band, infrared wavelength that is not as well focused at the retina-a situation difficult to address. To add confidence to the experimental results obtained, a theoretical thermodynamic model was developed to predict the minimal damage threshold for simultaneous wavelengths at 1 h post exposure. The new model calculations and the data obtained are compared with results from one currently accepted method of predicting relative exposure limits from multi-wavelength systems. In addition, the current ANSI-Z136-2000 standard was used to compute the combined MPEs for comparison with measured visible lesion thresholds. A total of 12 eyes were exposed using four different ratios of power levels (532/860 power rations) to determine the contribution to the damage levels from each wavelength. The experimental data were analyzed using probit analysis at both 1-h and 24-h post exposure to determine the minimum-visible-lesion (MVL) thresholds at ED50 values, and these thresholds at 24 h varied from 5.6 mW to 17 mW total intraocular power.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wavelength Selectable Solid-State Raman lasers in the Visible and Ultraviolet Ranges

Solid-state Raman lasers are known as important sources at normally difficult to access wavelengths, and our recent studies have shown that they also form the basis of a class of wavelength selectable lasers. This paper summarizes our recent studies in wavelength selectable Raman lasers in the visible (532-650 nm) and ultraviolet (266-321 nm). 

متن کامل

Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study

Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...

متن کامل

Therapeutic window of retinal photocoagulation with green (532-nm) and yellow (577-nm) lasers.

BACKGROUND AND OBJECTIVE The 577-nm (yellow) laser provides an alternative to the 532-nm (green) laser in retinal photocoagulation, with potential benefits in macular treatment and through ocular opacities. To assess relative risk of thermomechanical rupture of Bruch's membrane with yellow laser in photocoagulation, the therapeutic window, the ratio of threshold powers for mild coagulation and ...

متن کامل

Sensitivity of the Retina to Radiation Damage

Exposure of the retina of the rhesus monkey to visible and infrared radiation from CW optical sources like the Sun, xenon lamps, etc. produces small lesions or scotomata which may be classified as thermal or photochemical, depending on the wavelength and duration of exposure. The action spectrum for the production of retinal lesions has been determined for eight monochromatic laser wavelengths ...

متن کامل

Functional imaging with the multi-wavelength Adaptive Optics Scanning Laser Ophthalmoscope

The adaptive optics scanning laser ophthalmoscope may be used in multi-wavelength mode to allow simultaneous imaging and retinal stimulation and so probe retinal function. The wavelengths available are 532 nm, 658 nm and 840 nm. Typically the imaging is performed at 840 nm and precisely coincident retinal stimulation occurs in one of the visible wavelengths. Simultaneous multi-wavelength imagin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Health physics

دوره 90 3  شماره 

صفحات  -