Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial.

نویسندگان

  • Shinjo Sonoda
  • Yoshihiro Morino
  • Junya Ako
  • Mitsuyasu Terashima
  • Ali H M Hassan
  • Heidi N Bonneau
  • Martin B Leon
  • Jeffrey W Moses
  • Paul G Yock
  • Yasuhiro Honda
  • Richard E Kuntz
  • Peter J Fitzgerald
چکیده

OBJECTIVES We assessed the predictive value of minimum stent area (MSA) for long-term patency of sirolimus-eluting stents (SES) implantation compared to bare metal stents (BMS). BACKGROUND Although MSA is a consistent predictor of in-stent restenosis, its predictive value in BMS is still limited because of biologic variability in the restenosis process. METHODS From the SIRolImUS (SIRIUS) trial, 122 cases (SES: 72; BMS: 50) with complete serial intravascular ultrasound (IVUS) (baseline and 8-month follow-up) were analyzed. Postprocedure MSA and follow-up minimum lumen area (MLA) were obtained. Based on previous physiologic studies, adequate stent patency at follow-up was defined as MLA >4 mm(2). RESULTS In both groups, a significant positive correlation was observed between baseline MSA and follow-up MLA (SES: p < 0.0001, BMS: p < 0.0001). However, SES showed higher correlation than BMS (0.8 vs. 0.65) with a higher regression coefficient (0.92 vs. 0.59). The sensitivity and specificity curves identified different optimal thresholds of MSA to predict adequate follow-up MLA: 5 mm(2) for SES and 6.5 mm(2) for BMS. The positive predictive values with these cutoff points were 90% and 56%, respectively. CONCLUSIONS In this SIRIUS IVUS substudy, SES reduced both biologic variability and restenosis, resulting in increased predictability of long-term stent patency with postprocedure MSA. In addition, SES had a considerably lower optimal MSA threshold compared to BMS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis.

OBJECTIVES We sought to identify the frequency of incomplete stent apposition (ISA) in sirolimus-eluting stents (SES) and clarify its findings and clinical sequelae. BACKGROUND Late-acquired ISA has been reported in bare-metal stents (BMS) and brachytherapy and recently in drug-eluting stents. However, the characteristics of late ISA in SES have not been clarified. METHODS From the SIRIUS t...

متن کامل

Kommerell diverticulum associated with aberrant left subclavian artery and right-sided aortic arch.

SEARCH) study. Circulation 2004;109:1366–70. 30. Iijima R, Ndrepepa G, Mehilli J, Markwardt C, Bruskina O, Pache J et al. Impact of diabetes mellitus on long-term outcomes in the drug-eluting stent era. Am Heart J 2007;154:688–93. 31. Kawamoto T, Okura H, Koyama Y, Toda I, Taguchi H, Tamita K et al. The relationship between coronary plaque characteristics and small embolic particles during coro...

متن کامل

Plasma brain natriuretic peptide-guided therapy not yet justified.

1. Iakovow I, Schmidt T, Bonizzoni E, et al. Incidence, predictors and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005;293:2126–30. 2. Kuchulakanti PK, Chu WW, Torguson R, et al. Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus and paclitaxel-eluting stents. Circulation 2006;113; 1108 –13. 3. Alfonso F, Suarez A, ...

متن کامل

Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up.

BACKGROUND Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS Fifte...

متن کامل

Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients.

OBJECTIVES This study sought to evaluate the long-term arterial response after sirolimus-eluting stent implantation. BACKGROUND Sirolimus-eluting stents are effective in inhibiting neointimal hyperplasia without affecting plaque volume behind the stent struts at six months. METHODS Serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis over four years we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 43 11  شماره 

صفحات  -

تاریخ انتشار 2004