The Influence of Transient Processes on Vapor Intrusion Processes
نویسندگان
چکیده
A three dimensional vapor intrusion model was used to investigate the amount of time required to reach steady-state vapor intrusion rates. The effect of pressure fluctuations on vapor intrusion rates was also investigated. These results were obtained for a homogenous soil conceptual site model with groundwater located at 25 feet below ground surface. The time to achieve steady state ranged from approximately 6-12 months depending on geology. However, the time required for crack concentrations to return to zero after a vapor intrusion source had been removed was on the order of years. Pressure fluctuations can result in concentration spikes when the building pressure becomes negative. For highly permeable soils, the instantaneous mass flow rate into the building can be 2 times greater than steady state mass flow rates due to the effect that pressure fluctuations have on soil gas concentration profiles. The results provide insight about managing and characterizing vapor intrusion risks.
منابع مشابه
Influence of unsuitable operational conditions on the transient performance of a small hydrogen liquefier
Joule-Thomson cooling systems are used in refrigeration processes such as cryogenic gas liquefaction. Although extensive studies have been carried out by researchers, most of them include cryogenic heat exchangers and their associated fields. In the current study, an attempt was made to indicate the effect of using inappropriate operational conditions in a cryogenic Joule-Thomson cooling system...
متن کاملEstimating of Crystallization Temperature of Mard-Abad (Karaj) Granitic Intrusion Using Mineralogy, Geochemistry and Morphology of Zircon Crystals
Mard-abad calc-alkaline granite formed along the margin of active pull-apart or intra-continental plates, and it is post-collision granite type. Granophyric, perthitic and myrmekitic are main textures that could form from crystallization of hypersolvus source magma, which occurred under water vapor pressure of approximately 2 kb. During this study the temperature of formation of these granites ...
متن کاملTransient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation
Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...
متن کاملPetroleum Hydrocarbons And Chlorinated Hydrocarbons Differ In Their Potential For Vapor Intrusion
Response issued draft vapor intrusion guidance (EPA, 2002), which specifically states that it is not recommended for Subtitle I underground storage tank (UST) sites. EPA's Office of Underground Storage Tanks (OUST) is thus currently developing guidance to address petroleum vapor intrusion (PVI) at UST sites. OUST has consulted on several occasions with experts in the field of vapor intrusion an...
متن کاملPetroleum Hydrocarbons And Chlorinated Solvents Differ In Their Potential For Vapor Intrusion
Response issued draft vapor intrusion guidance (EPA, 2002), which specifically states that it is not recommended for Subtitle I underground storage tank (UST) sites. EPA's Office of Underground Storage Tanks (OUST) is thus currently developing guidance to address petroleum vapor intrusion (PVI) at UST sites. OUST has consulted on several occasions with experts in the field of vapor intrusion an...
متن کامل