OBJECTIVE We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. METHODS Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. RESULTS The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). CONCLUSION The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress.
منابع مشابه
Reducing the impact of intensive care unit mattress compressibility during CPR: a simulation-based study
Background The depth of chest compression (CC) during cardiac arrest is associated with patient survival and good neurological outcomes. Previous studies showed that mattress compression can alter the amount of CCs given with adequate depth. We aim to quantify the amount of mattress compressibility on two types of ICU mattresses and explore the effect of memory foam mattress use and a backboard...
متن کاملShort-Range Vital Signs Sensing Based on EEMD and CWT Using IR-UWB Radar
The radar sensor described realizes healthcare monitoring capable of detecting subject chest-wall movement caused by cardiopulmonary activities and wirelessly estimating the respiration and heartbeat rates of the subject without attaching any devices to the body. Conventional single-tone Doppler radar can only capture Doppler signatures because of a lack of bandwidth information with noncontact...
متن کاملA Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated re...
متن کاملUse of Backboard and Deflation Improve Quality of Chest Compression When Cardiopulmonary Resuscitation Is Performed on a Typical Air Inflated Mattress Configuration
No study has examined the effectiveness of backboards and air deflation for achieving adequate chest compression (CC) depth on air mattresses with the typical configurations seen in intensive care units. To determine this efficacy, we measured mattress compression depth (MCD, mm) on these surfaces using dual accelerometers. Eight cardiopulmonary resuscitation providers performed CCs on manikins...
متن کاملUltra Wideband Indoor Radio Channel Measurements
This paper explains the ultra wideband (UWB) indoor radio channel measurement procedure performed at the main building at the University of Oulu, Finland. The measurement campaign included rooms with various sizes and layouts. The frequency response of the radio channel was recorded using a network analyzer in frequency sweep mode. The impulse response of the radio channel was calculated by tak...