Development and Validation of a High-Pressure Liquid Chromatography Method for the Determination of Chemical Purity and Radiochemical Purity of a [68Ga]-Labeled Glu-Urea-Lys(Ahx)-HBED-CC (Positron Emission Tomography) Tracer

نویسندگان

  • Silvia Migliari
  • Antonino Sammartano
  • Maura Scarlattei
  • Giulio Serreli
  • Caterina Ghetti
  • Carla Cidda
  • Giorgio Baldari
  • Ornella Ortenzia
  • Livia Ruffini
چکیده

Background: Prostate-specific membrane antigen (PSMA) has gained high attention as a useful biomarker in the imaging evaluation of prostate cancer with positron emission tomography (PET) during recent years. [68Ga]-labeled Glu-urea-Lys(Ahx)-HBED-CC ([68Ga]-PSMA-HBED-CC) is a novel PSMA inhibitor radiotracer which has demonstrated its suitability in detecting prostate cancer. Preparation conditions may influence the quality and in vivo behavior of this tracer, and no standard procedure for the quality control (QC) is available. The aim of this study was to develop a new rapid and simple high-pressure liquid chromatography method of analysis for the routine QCs of [68Ga]-PSMA-HBED-CC to guarantee the high quality of the radiopharmaceutical product before release. Methods: A stepwise approach was used based on the quality by design concept of the International Conference of Harmonisation Q2 (R1) and Q8 (Pharmaceutical Development) guidelines in accordance with the regulations and requirements of European Association of Nuclear Medicine, Society of Nuclear Medicine, International Atomic Energy Agency, World Health Organization, and Italian Association of Nuclear Medicine and Molecular Imaging. The developed analytical test method was validated because a specific monograph in the pharmacopoeia is not available for [68Ga]-PSMA-HBED-CC. Results: The purity and quality of the radiopharmaceutical obtained according to the proposed method resulted high enough to safely administrate it to patients. An excellent linearity was found between 0.8 and 5 μg/mL, with a detection limit of 0.2 μg/mL. Assay imprecision (% CV) was <2%. Conclusions: The developed method to assess the radiochemical and chemical purity of [68Ga]-PSMA-HBED-CC is rapid, accurate, and reproducible, allowing routinely the use of this PET tracer as a diagnostic tool for imaging prostate cancer and also assuring patient safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis of an Al18F radiofluorinated GLU-UREA-LYS(AHX)-HBED-CC PSMA ligand in an automated synthesis platform

Background Overexpression of prostatic membrane antigen (PSMA) is associated with the progression and prognosis of prostate cancer. There are numerous studies using this peptide with the 68Ga radionuclide. Previous methods to synthetize 18F-labeled PSMA ligands with complexes [18F]AlF2+ have been achieved. However, these reported syntheses were performed manually, using small volumes. Therefore...

متن کامل

Novel Preclinical and Radiopharmaceutical Aspects of [68Ga]Ga-PSMA-HBED-CC: A New PET Tracer for Imaging of Prostate Cancer

The detection of prostate cancer lesions by PET imaging of the prostate-specific membrane antigen (PSMA) has gained highest clinical impact during the last years. 68Ga-labelled Glu-urea-Lys(Ahx)-HBED-CC ([68Ga]Ga-PSMA-HBED-CC) represents a successful novel PSMA inhibitor radiotracer which has recently demonstrated its suitability in individual first-in-man studies. The radiometal chelator HBED-...

متن کامل

Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]

Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...

متن کامل

Pharmacokinetic studies and human absorbed dose estimation of 68Ga-(4 {[(bis (phosphonomethyl)) carbamoyl] methyl}-7,10-bis(carboxymethy l) -1,4,7,10-tetraazacyclododec-1-yl) acetic acid

Background: In this study, human absorbed dose of a newly introduced bone imaging agent, 68Ga-(4-{[(bis(phosphonomethyl))carbamoyl]methyl}-7,10-bis(carboxymethyl)-1,4,7,10-tetraazacyclododec-1-yl) acetic acid (68Ga-BPAMD), was estimated based on the rats data. Materials and Methods: 68Ga was obtained from the 68Ge/68Ga generator and it's radionuclidic and radiochemical purities were investigate...

متن کامل

Preparation and Quality Control of 68Ga-Citrate for PET Applications

  Objective(s): In nuclear medicine studies, gallium-68 (68Ga) citrate has been recently known as a suitable infection agent in positron emission tomography (PET). In this study, by applying an in-house produced 68Ge/68Ga generator, a simple technique for the synthesis and quality control of 68Ga-citrate was introduced; followed by preliminary animal studies. Methods: 68GaCl3 eluted from the ge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2017