Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia
نویسندگان
چکیده
Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breathhold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients (65.4 ± 12.3 years, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging (15 ± 7 sec vs. 293 ± 104 sec, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.
منابع مشابه
Free-breathing real-time cardiac cine MR for evaluation of left-ventricular function: Comparison to standard multi-breath-hold cardiac cine MR in 50 patients
Background Electrocardiogram (ECG)-gated breath-hold cardiac cine magnetic resonance imaging (MRI) is generally accepted as the gold standard for left-ventricular (LV) volume assessment. However, it may fail in patients with arrhythmia, impaired breath-hold capacity, and poor ECG gating. Recently, sparse real-time (RT) cine using a prototype sequence with sparse sampling and iterative reconstru...
متن کاملHighly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.
For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm...
متن کاملSingle breath-hold real-time MR cardiac cine for evaluation of left ventricular function
Background Magnetic Resonance (MR) cardiac cine is generally accepted as the gold standard for left ventricular (LV) volume assessment. Recently, Real-Time (RT) cine with sparse sampling technique and iterative reconstruction has been applied to accelerate cine MR. However, in prospective electrocardiogram (ECG) triggered RT cine MR, it may be difficult to capture the true end diastole phase be...
متن کاملCompressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold
BACKGROUND Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard ci...
متن کاملMagnetic resonance assessment of left ventricular volumes and mass using a single-breath-hold 3D k-t BLAST cine b-SSFP in comparison with multiple-breath-hold 2D cine b-SSFP
OBJECTIVE To assess the feasibility of single-breath-hold three-dimensional cine b-SSFP (balanced steady-state free precession gradient echo) sequence (3D-cine), accelerated with k-t BLAST (broad-use linear acquisition speed-up technique), compared with multiple-breath-hold 2D cine b-SSFP (2D-cine) sequence for assessment of left ventricular (LV) function. METHODS Imaging was performed using ...
متن کامل