Preliminary Studies on the Feasibility of Addition of Vertex View to Conventional Brain SPECT' C.Y

نویسنده

  • Y. Zhang
چکیده

We have investigated the improvement in resolution and sensitivity for brain imaging which would result by the addition of a single stationary vertex view to the tomographic data. This method has the practical advantage of being relatively inexpensive and easy to implement. The uniform Cramer Rao bound is a plot of the minimum achievable standard deviation for estimating the pixel intensity as a function of the bias gradient length. Uniform CR bound analysis indicated an improvement in performance when the vertex detector is added, especially for centrally located pixels for which improvement is seen over the useful depth for brain imaging. Simulation experiments were done with a simple six slice phantom and with the Hoffman brain phantom. Visual inspection of the reconstructed images showed improved resolution and noise characteristics over reconstructed images without the vertex data. Quantitatively, substantial reduction in mean square error was observed for a plane close to the vertex detector. Improvement reduced as distance from the vertex detector is increased. Background activities inside the field of view of the vertex detector but not the tomograph were represented by several blobs of activity on a plane lying outside the reconstruction volume. This activity was estimated by 3D spline fitting jointly with the image reconstruction process. Adding the vertex view to conventional brain SPECT should lead to improved cortical imaging, and to moderate improvement for deep structures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary Studies on the Feasibility of Addition of Vertex View to Conventional Brain SPECT

We have investigated the improvement in resolution and sensitivity for brain imaging which would result by the addition of a single stationary vertex view to the tomographic data. This method has the practical advantage of being relatively inexpensive and easy to implement. The uniform Cramer Rao bound is a plot of the minimum achievable standard deviation for estimating the pixel intensity as ...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)

Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...

متن کامل

Diagnostic efficiency of 68Ga-DOTATATE PET/CT as compared to 99mTc-Octreotide SPECT/CT and conventional morphologic modalities in neuroendocrine tumors

Objective(s): In view of somatostatin receptor (SSR) expression on cell membranes of the majority of neuroendocrine tumors (NETs), functional imaging exploiting analogs of SSR alongside the anatomical imaging is the mainstay of this diagnostic modality. In this prospective study, we assessed and directly compared the diagnostic parameters of 68Ga-DOTATATE PET/CT and 99...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004