Measurement of the resonance frequency of single bubbles using a laser Doppler vibrometer.
نویسندگان
چکیده
The behavior of bubbles confined in tubes and channels is important in medical and industrial applications. In these small spaces, traditional means of experimentally observing bubble dynamics are often impossible or significantly perturb the system. A laser Doppler vibrometer (LDV) requires a narrow (<1 mm diameter) line-of-sight access for the beam and illumination of the bubble does not perturb its dynamics. LDV measurements of the resonance frequency of a bubble suspended in a small tank are presented to illustrate the utility of this measurement technique. The precision of the technique is similar to the precision of traditional acoustic techniques.
منابع مشابه
Analysis of human pulse performance using the device of laser Doppler vibrometer
This article has no abstract.
متن کاملMass sensing with resonating ultra-thin silicon beams detected by a double-beam laser Doppler vibrometer
This paper reports on mass sensing with 33 nm thick single-crystalline cantilevers by a double-beam laser Doppler vibrometer. The resonant frequency of an oscillating thin cantilever beam is very sensitive to a loaded mass. However, the drift of the resonance, due to gas adsorption and mechanical instability, limits the minimum detectable mass in general. Two cantilevers for sensing and its ref...
متن کاملMultipoint laser Doppler vibrometry with single detector: principles, implementations, and signal analyses.
A 20-point laser Doppler vibrometer with single photodetector is presented for noncontact dynamic measurement. A 5×4 beam array with various frequency shifts is generated by a 1.55 μm distributed feedback laser and four acousto-optic devices, and illuminating different points on vibrating objects. The reflected beams are coupled into a single-mode fiber by a pigtailed collimator and interfere w...
متن کاملAcoustic-to-Seismic Landmine Detection Using a Continuously Scanning Laser Doppler Vibrometer
A single beam laser Doppler vibrometer (LDV) has been used in acoustic-to-seismic landmine detection in a stop-andstare scanning mode [Sabatier, J. M. and Xiang, N. IEEE Trans. Geoscience and Remote Sensing 39, 2001, pp.11461154.; Xiang, N. and Sabatier, J. M., J. Acoust. Soc. Am. 113, Mar. 2003]. One of the major requirements is the operational scanning speed in the acoustic detection methods....
متن کاملTissue blood flow measurement by laser Doppler technique
Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 123 6 شماره
صفحات -
تاریخ انتشار 2008