Phantom and in-vivo measurements of dose exposure by image-guided radiotherapy (IGRT): MV portal images vs. kV portal images vs. cone-beam CT.
نویسندگان
چکیده
PURPOSE Positioning verification is usually performed with treatment beam (MV) portal images (PI) using an electronic portal imaging device (EPID). A new alternative is the use of a low energy photon source (kV) and an additional EPID mounted to the accelerator gantry. This system may be used for PI or--with rotating gantry--as cone-beam CT (CBCT). The dose delivered to the patient by different imaging processes was measured. METHODS AND MATERIALS A total of 15 in-vivo dose measurements were done in five patients receiving prostate IMRT. For anterior-posterior (AP) and lateral PI with MV and kV photons measurement points were inside the rectum and at the patient's skin. Dose for CBCT was measured in the rectum. Additional measurements for CBCT were done in a cylindrical CT-dose-index (CTDI) phantom to determine peripheral, central and weighted CTDI. RESULTS The dose for AP MV PI was 57.8 mGy at the surface and 33.9 mGy in the rectum, for lateral MV PI 69.4 mGy and 31.7 mGy, respectively (5 MU/exposure). The dose for AP kV PI was 0.8 mGy at the surface and 0.2 mGy in the rectum, for lateral PI 1.1 mGy and 0. 1 mGy, respectively. For a CBCT the rectal dose was 17.2 mGy. The peripheral CTDI was 23.6 mGy and the center dose was 10.2 mGy, resulting in a weighted CTDI of 19.1 mGy in the phantom and an estimated surface dose of < or =28 mGy. CONCLUSIONS Even taking into account an RBE (Relative Biological Effectiveness) of 2 for kV vs. MV radiation, for kV PI the delivered dose is lower and image quality is better than for MV PI. CBCT provides a 3D-image dataset and dose exposure for one scan is lower than for two MV PI, thus rendering frequent volume imaging during a fractionated course of radiotherapy possible.
منابع مشابه
Comparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کاملAutomated Quality Assurance for Image‐Guided Radiation Therapy
The use of image-guided patient positioning requires fast and reliable Quality Assurance (QA) methods to ensure the megavoltage (MV) treatment beam coincides with the integrated kilovoltage (kV) or volumetric cone-beam CT (CBCT) imaging and guidance systems. Current QA protocol is based on visually observing deviations of certain features in acquired kV in-room treatment images such as markers,...
متن کاملA feasibility study on the use of MV-CBCT images for urgent palliative treatment planning
Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...
متن کاملTowards Personalized Imaging in Image-guided Radiotherapy
Recently, with the advent of linear accelerators equipped with on-board x-ray images and advanced imaging technologies, image-guided radiotherapy (IGRT) has gained worldwide momentum in the radio therapeutic management of cancers in terms of volumetric information-based accurate tumor localization, real-time patient setup and margin reduction [1,2]. The involved technologies include digital rad...
متن کاملThe Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography
Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
دوره 85 3 شماره
صفحات -
تاریخ انتشار 2007