How much is catheter flow influenced by the use of closed luer lock access devices?
نویسندگان
چکیده
BACKGROUND To reduce infection risks in patients on hemodialysis with a long term central venous catheter, different types of closed luer lock access devices are used on the arterial and venous catheter hub. Although those connectors create a mechanically and microbiologically closed system in between two dialysis sessions, no data are available on the resistance those connectors exert on the blood flow during dialysis. Therefore, in the present study, flow resistance was determined in three different connectors. METHODS In an in vitro setup, different connectors were attached in between a male (Bellco BL 307 dialysis tubing) and female luer: BD Q-Syte (Becton-Dickinson, Utah, USA), second edition Tego (ICU Medical, CA, USA), and Swan-LockU connector (Codan, Lensahn, Germany). For a wide range of water flow rates, pressure-flow relationships were measured, simulating catheter inflow as well as catheter outflow, by reversing the flow direction. Resistances were compared to a simple male-female connection, as in a standard bloodline-catheter connection, and mathematical corrections were performed for the use of water instead of blood. RESULTS For a blood flow of 500 mL/min, simulating clinical dialysis, the additional pressure drop is 118 mmHg (Becton Dickinson), 52 mmHg (Codan), and 23 mmHg (Tego) in the case of catheter inflow, while it is 74 mmHg (Becton Dickinson), 40 mmHg (Codan), and 27 mmHg (Tego) in the case of catheter outflow. Resistances are also depending on the type of tubing as used during dialysis. CONCLUSIONS In conclusion, the Tego and Codan connector show promising results for the use on a catheter hub during and in between dialysis sessions. Whether those resistances are in the safe range without the incidence of blood hemolysis will soon be investigated in an in vivo study.
منابع مشابه
How much is red blood cell fragmentation increased by the use of closed luer lock access devices on catheter hubs?
The opening and manipulation of central venous (CV) catheters before and after each dialysis event might result in catheter-related blood stream infections [1–3]. In order to reduce those infection risks, different types of closed luer lock access devices are commercially available. Such connectors are placed on the arterial and venous catheter hub and are designed with a split septum of medica...
متن کاملA continuous quality improvement project to decrease hemodialysis catheter infections in pediatric patients: use of a closed luer-lock access cap.
Catheter infections are a significant problem in pediatric hemodialysis. To reduce infection rates, the use of closed luer-lock access connectors, which create a mechanically and microbiogically closed system while allowing unobstructed blood flow, was implemented Infection rates fell from 7.8 infections per 1000 patient days to 3.65 infections per 1000 patient days after the switch to the clos...
متن کاملRisk of infection due to medical interventions via central venous catheters or implantable venous access port systems at the middle port of a three-way cock: luer lock cap vs. luer access split septum system (Q-Syte)
BACKGROUND Many cancer patients receive a central venous catheter or port system prior to therapy to assure correct drug administration. Even appropriate hygienic intervention maintenance carries the risk of contaminating the middle port (C-port) of a three-way cock (TWC), a risk that increases with the number of medical interventions. Because of the complexity of the cleaning procedure with di...
متن کاملIs Taurolidine-citrate an effective and cost-effective hemodialysis cathe-ter lock solution? A systematic review and cost- effectiveness analysis
Background: Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other ...
متن کاملEffectiveness of Permanent Implantable Catheter (Polysite) in Children with Cancer
Abstract Background Totally implantable central venous access devices (ports) have been available for over 10 years, but have not been achieved widespread use in pediatric oncology patients. Ports facilitate the administration of chemotherapy in children with cancer. Materials and Methods In this study, early complications of implantable central venous access devices in children with diff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 22 10 شماره
صفحات -
تاریخ انتشار 2007