A Comparative Verification of Force Calibration Machines Used by an Accredited Laboratory
نویسندگان
چکیده
− One of the most important activities of the National Accreditation Body (NAB) is the organisation of a series of comparisons (ILC), at the National level, to verify the measurements capability of the accredited laboratories For evaluation of the best measurement capability of AEP Transducers -an calibration accredited laboratory for Force quantity over several years (1999-2005) are carried out measurements during accreditation and reaccreditation process of this SIT Centre, whose main results are reported in the following. The results were evaluated using the En normalised error according to the SIT Doc-511. The metrological procedures applied and the results of the accreditation of the SIT Centre, show that the best measurement capabilities and the total uncertainty, including transfer standards contribution and long term stability, can be considered as well: ± 50 ppm for the 50 kN dead weight machine (DWM); ± 250 ppm for the 200 kN Comparison machine; ± 350 ppm for the 1 MN Comparison machine (compression) ± 250 ppm for the 1 MN Comparison machine (tension).
منابع مشابه
Comparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کاملA simple method for validation and verification of pipettes mounted on automated liquid handlers.
We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared in quadruplicates in a flat-bottom 96-well microtiter plate, manually using calibrated pipettes. Each pipette...
متن کاملAppendix to Iaea Calibration Certificate Well Type Chamber and Electrometer Calibration Procedure at the Iaea Dosimetry Laboratory
At SSDLs the recommended detector for the calibration of all brachytherapy photon sources, as well as for the calibration of intravascular beta sources, is an appropriately calibrated well type chamber. For SSDLs the preferred method for traceability in the source calibrations is to have the well type chamber calibrated against the primary standard at the PSDL. However, due to practical reasons...
متن کاملA comparative study of performance of K-nearest neighbors and support vector machines for classification of groundwater
The aim of this work is to examine the feasibilities of the support vector machines (SVMs) and K-nearest neighbor (K-NN) classifier methods for the classification of an aquifer in the Khuzestan Province, Iran. For this purpose, 17 groundwater quality variables including EC, TDS, turbidity, pH, total hardness, Ca, Mg, total alkalinity, sulfate, nitrate, nitrite, fluoride, phosphate, Fe, Mn, Cu, ...
متن کاملInvestigation of unbalanced magnetic force in permanent magnet brushless dc machines with diametrically asymmetric winding
The purpose of this paper is the calculation of Unbalanced Magnetic Force (UMF) in permanent magnet brushless DC (PMBLDC) machines with diametrically asymmetric winding and investigation of UMF variations in the presence of phase advance angle. This paper presents an analytical model of UMF in surface mounted PMBLDC machines that have a fractional ratio of slot number to pole number. This model...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009