Fetus-supporting flexible manipulator with balloon-type stabilizer for endoscopic intrauterine surgery.
نویسندگان
چکیده
BACKGROUND Minimally invasive endoscopic fetal surgery enables intrauterine intervention with reduced risk to the mother and fetus. A novel surgical manipulator is described for stabilizing the fetus and restraining it from floating free during endoscopic intrauterine surgery. METHODS We designed and fabricated a prototype fetus-supporting manipulator equipped with flexible joint and bending mechanisms and a soft balloon stabilizer. The flexible joint and bending mechanisms enable the stabilizer to reach the target sites within the confined space of the uterus under the guidance of an ultrasound device. The balloon stabilizer could be inserted into the uterus through a small incision. RESULTS The accuracy evaluation showed that the maximum error of the bending mechanism was as small as 7 mm and the standard deviation of the joint mechanism was just 1.6 degrees. In the experiments using a fetus model, the manipulator could be well controlled with guidance from ultrasound images and its bending mechanism with the balloon stabilizer could be clearly visualized while stabilizing the fetus model. CONCLUSIONS The manipulator has the potential to be used in minimally invasive intrauterine surgery, although further improvements and experiments remain to be carried out.
منابع مشابه
Iatrogenic Uterine Perforation with Kronner Uterine Manipulator
Iatrogenic uterine perforation due to initial overinflation of the Kronner uterine manipulator balloon through the balloon port is previously unreported. A 37-year-old multipara with a 1 year history of dysmenorrhea, menorrhagia, and post coital spotting desired permanent sterilization following 9 years of copper intrauterine device (IUD) use. At the onset of the procedure a Kronner uterine man...
متن کاملBalloon dilatation of the aortic valve in the fetus: a report of two cases.
Because they had irreversible damage to the left ventricular myocardium none of 12 patients with critical aortic stenosis diagnosed prenatally survived after postnatal treatment. This experience prompted three attempts at intrauterine balloon dilatation of the aortic valve in two fetuses with this condition. On each attempt the balloon catheter was successfully delivered to the left ventricle. ...
متن کاملDesign of Flexible Micro Manipulator for Neurosurgery
Today, endoscopic surgery is widely used in the field of abdominal and urological surgeries. But it is still difficult to be applied on the tumor resection in neurosurgery because the work space is very narrow and tumor is seated deeply under normal brain. The authors developed a flexible micro manipulator for the resection of deeply seated tumor three years ago, but detail design and fabricati...
متن کاملOptimal Trajectory of Flexible Manipulator with Maximum Load Carrying Capacity
In this paper, a new formulation along with numerical solution for the problem of finding a point-to-point trajectory with maximum load carrying capacities for flexible manipulators is proposed. For rigid manipulators, the major limiting factor in determining the Dynamic Load Carrying Capacity (DLCC) is the joint actuator capacity. The flexibility exhibited by light weight robots or by robots o...
متن کاملFlexible microsensor technology for real-time navigation tracking in balloon sinus ostial dilation
BACKGROUND Microsensor navigation has the potential to aid balloon sinus ostial dilation by providing real-time tracking of balloon devices within the complex anatomy of the sinonasal cavities. OBJECTIVE This feasibility study evaluated the incorporation of a new microsensor technology into a flexible guidewire for use with current instruments in balloon sinus ostial dilation. METHODS A ret...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The international journal of medical robotics + computer assisted surgery : MRCAS
دوره 4 3 شماره
صفحات -
تاریخ انتشار 2008