Radiation shielding materials and radiation scatter effects for interventional radiology (IR) physicians.

نویسندگان

  • J P McCaffrey
  • F Tessier
  • H Shen
چکیده

PURPOSE To measure the attenuation effectiveness and minimize the weight of new non-Pb radiation shielding materials used for radiation protection by interventional radiology (IR) physicians, to compare the accuracy of the different standard measurement geometries of these materials, and to determine x-ray qualities that correspond to the scattered radiation that IR physicians typically encounter. METHODS Radiation attenuation capabilities of non-Pb materials were investigated. Typically, most studies of non-Pb materials have focused on the attenuating properties of metal powders. In this study, layers of materials incorporating non-Pb powdered compounds such as Bi(2)O(3), Gd(2)O(3), and BaSO(4) were measured individually, as bilayers, and as a Bi(2)O(3)-loaded hand cream. Attenuation measurements were performed in narrow-beam (fluorescence excluded) and broad beam (fluorescence included) geometries, demonstrating that these different geometries provided significantly different results. The Monte Carlo (MC) program EGSnrc was used to calculate the resulting spectra after attenuation by radiation shielding materials, and scattered x-ray spectra after 90° scattering of eight ASTM Standard primary x-ray beams. Surrogate x-ray qualities that corresponded to these scattered spectra were tabulated. RESULTS Radiation shielding materials incorporating Bi(2)O(3) were found to provide equivalent or superior attenuation compared with commercial Pb-based and non-Pb materials across the 60-130 kVp energy range. Measurements were made for single layers of the Bi(2)O(3) compound and for bilayers where the ordering was low atomic number (Z) layer closest to x-ray source∕high Z (Bi(2)O(3)) layer farthest from the x-ray source. Narrow-beam Standard test methods which do not include the contribution from fluorescence overestimated the attenuating capabilities of Pb and non-Pb materials. Measurements of a newly developed, quick-drying, and easily removable Bi(2)O(3)-loaded hand cream demonstrated better attenuation capabilities than commercial Bi(2)O(3)-loaded gloves. Scattered radiation measurements and MC simulations illustrated that the spectra resulting from 90° scattering of primary x-ray beam qualities can be approximated by surrogate x-ray qualities which are more representative of the radiation actually encountered by IR physicians. A table of surrogate qualities of the eight ASTM F2547-06 Standard qualities was compiled. CONCLUSIONS New non-Pb compound materials, particularly single layers or bilayers incorporating Bi(2)O(3), can reduce the weight of radiation protection materials while providing equivalent or better protection compared to Pb-based materials. Attenuation measurements in geometries that exclude the contribution from fluorescence substantially underestimate the quantity of transmitted radiation. A new Bi(2)O(3)-loaded hand cream demonstrated a novel and effective approach for hand protection. Standard testing protocols for radiation protection materials used by IR physicians specify a wider kVp range than is necessary. A more realistic range would acknowledge the lower kVp resulting from scatter and allow IR physicians to confidently utilize lighter-weight materials while still receiving adequate protection. Standards protocols incorporating the adjustments described in this work would maintain the safety of IR personnel and lessen the physical repercussions of long hours wearing unnecessarily heavy radiation protection garments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heavy metal pad shielding during fluoroscopic interventions.

Significant direct and scatter radiation doses to patient and physician may result from routine interventional radiology practice. A lead-free disposable tungsten antimony shielding pad was tested in phantom patients during simulated diagnostic angiography procedures. Although the exact risk of low doses of ionizing radiation is unknown, dramatic dose reductions can be seen with routine use of ...

متن کامل

Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures.

At present, interventional radiology (IVR) tends to involve long procedures (long radiation duration), and physicians are near to the source of scattered radiation. Hence, shielding is critical in protecting physicians from radiation. Protective aprons and additional lead-shielding devices, such as tableside lead drapes, are important means of protecting the physician from scattered radiation. ...

متن کامل

Comprehensive TLD dosimetry of physicians and patients during interventional angiography procedures to estimate the risk of radiation deterministic effect

Introduction: Interventional angiography procedures are increasingly used today. These techniques require a long time of standing near the patient and x-ray tube which lead to increase the radiation-dose of the staff and interventionists. This may also, in turn, lead to the occurrence of radiation deterministic effects. Since a large number of interventional radiology were perf...

متن کامل

Recommendations for occupational radiation protection in interventional cardiology.

The radiation dose received by cardiologists during percutaneous coronary interventions, electrophysiology procedures and other interventional cardiology procedures can vary by more than an order of magnitude for the same type of procedure and for similar patient doses. There is particular concern regarding occupational dose to the lens of the eye. This document provides recommendations for occ...

متن کامل

Comparing strategies for operator eye protection in the interventional radiology suite.

PURPOSE To evaluate the impact of common radiation-shielding strategies, used alone and in combination, on scattered dose to the fluoroscopy operator's eye. MATERIALS AND METHODS With an operator phantom positioned at the groin, upper abdomen, and neck, posteroanterior low-dose fluoroscopy was performed at the phantom patient's upper abdomen. Operator lens radiation dose rate was recorded wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 7Part1  شماره 

صفحات  -

تاریخ انتشار 2012