Topographic Findings of the Porcine Cornea

نویسندگان

  • Jens HEICHEL
  • Frank WILHELM
  • Kathleen S. KUNERT
  • Thomas HAMMER
چکیده

The porcine eye is often used as an ex vivo animal model in ophthalmological research. It is well suited for investigations concerning refractive surgery; however, corneal topography data are scarce. This study investigated the corneal topography and pachymetry of the porcine eye to provide further reproducible data. We evaluated freshly enucleated porcine eyes (n = 16) by performing computerized corneal topographies (Orbscan® IIz, Bausch and Lomb, Rochester, NY, USA). We assessed the steepest and flattest keratometric powers (K1 and K2, units in diopters (D)), astigmatism (D), white-to-white (WTW) diameter (mm), thinnest point pachymetry (µm), anterior and posterior best-fit sphere (BFS) (D), refractive power of the anterior and posterior curvatures, and total refractive power of the cornea (D). The mean keratometric powers were 39.6 ± 0.89 D (K1) and 38.5 ± 0.92 D (K2), and the mean astigmatism was 1.1 ± 0.78 D. The mean WTW diameter was 13.81 ± 0.83 mm, and the mean corneal thickness was 832.6 ± 40.18 µm. The BFSs were 38.14 ± 0.73 D (anterior) and 42.56 ± 1.15 D (posterior), and the mean refractive powers were 43.27 ± 1.08 D (anterior) and -5.15 ± 0.20 D (posterior); therefore, the mean of the total refractive power was 38.16 ± 1.00 D. The topography and pachymetry of the porcine cornea showed a specific configuration differing from the human cornea. When using animal ex vivo models such as porcine corneas for experimental corneal surgery, findings such as these should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fusion of information from Keratoscopic and Scheimpflug images

Topographic analysis systems used to analyse the cornea profile have some limitations due to the aspheric nature of the cornea. In many cases the cornea is modelled by a spherocylindrical surface. However the normal cornea is aspheric and flattened from the center to the periphery. Moreover diseased and postsurgical corneas rarely approximate a spherocylindrical surface. Topographic analysis sy...

متن کامل

Isolation and Culture of Porcine Corneal Cells

Permeation of a drug through the cornea may be studied in vitro by using either the excised cornea of slaughtered animals or an organotypic cornea construct [1]. To compare drug permeability data reported in the literature for excised porcine cornea [2] with those from cornea constructs, the cultivation of an organotypic porcine cornea is required. The porcine cornea consists of three major cel...

متن کامل

Evaluation of the Efficacy of Excimer Laser Ablation of Cross-Linked Porcine Cornea

BACKGROUND Combination of riboflavin/UVA cross-linking (CXL) and excimer laser ablation is a promising therapy for treating corneal ectasia. The cornea is strengthened by cross-linking, while the irregular astigmatism is reduced by laser ablation. This study aims to compare the efficacy of excimer laser ablation on porcine corneas with and without cross-linking. METHODS AND FINDINGS The porci...

متن کامل

Prediction of Corneal Condition After Corneal Ring Implantation in Keratoconus Patients

Background: Keratoconus is a common complication among corneal defects. As a result of expeditious and extensive progress of medical science in recent decades, corneal ring implantation has turned into a successful surgical procedure to correct the vision of Keratoconus patients; however, selecting the right patient is essential in the success of the operation. The prediction of corneal conditi...

متن کامل

Human corneal equivalent as cell culture model for in vitro drug permeation studies.

AIMS For the study of transcorneal in vitro permeation of ophthalmic drugs, excised animal cornea or corneal epithelial cell culture are frequently used as a replacement for the human cornea. The main purposes of this study were to reconstruct a complete human organotypic cornea equivalent, consisting of all three different cell types (epithelial, stromal, and endothelial); to test the barrier ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016