Repeatability of shear wave elastography in liver fibrosis phantoms—Evaluation of five different systems
نویسندگان
چکیده
This study aimed to assess and validate the repeatability and agreement of quantitative elastography of novel shear wave methods on four individual tissue-mimicking liver fibrosis phantoms with different known Young's modulus. We used GE Logiq E9 2D-SWE, Philips iU22 ARFI (pSWE), Samsung TS80A SWE (pSWE), Hitachi Ascendus (SWM) and Transient Elastography (TE). Two individual investigators performed all measurements non-continued and in parallel. The methods were evaluated for inter- and intraobserver variability by intraclass correlation, coefficient of variation and limits of agreement using the median elastography value. All systems used in this study provided high repeatability in quantitative measurements in a liver fibrosis phantom and excellent inter- and intraclass correlations. All four elastography platforms showed excellent intra-and interobserver agreement (interclass correlation 0.981-1.000 and intraclass correlation 0.987-1.000) and no significant difference in mean elasticity measurements for all systems, except for TE on phantom 4. All four liver fibrosis phantoms could be differentiated by quantitative elastography, by all platforms (p<0.001). In the Bland-Altman analysis the differences in measurements were larger for the phantoms with higher Young's modulus. All platforms had a coefficient of variation in the range 0.00-0.21 for all four phantoms, equivalent to low variance and high repeatability.
منابع مشابه
Shear wave elastography of the supraspinatus muscle and tendon: Repeatability and preliminary findings.
Shear wave elastography (SWE) is a promising tool for estimating musculoskeletal tissue properties, but few studies have rigorously assessed its repeatability and sources of error. The objectives of this study were to assess: (1) the extent to which probe positioning error and human user error influence measurement accuracy, (2) intra-user, inter-user, and day-to-day repeatability, and (3) the ...
متن کاملIntra-Individual Comparison between 2-D Shear Wave Elastography (GE System) and Virtual Touch Tissue Quantification (Siemens System) in Grading Liver Fibrosis.
Ultrasound-based shear wave elastography (SWE) has recently gained substantial attention for non-invasive assessment of liver fibrosis. The purpose of this study was to perform an intra-individual comparison between 2-D shear wave elastography (2-D-SWE with a GE system) and Virtual Touch Tissue Quantification (VTTQ with a Siemens system) to assess whether these can be used interchangeably to gr...
متن کاملLiver elastography - an update.
Liver fibrosis evaluation is very important for treatment and prognosis in patients with chronic liver disease. The "gold-standard" method for liver fibrosis assessment is still considered to be the liver biopsy, but in the last years non-invasive methods have increasingly been used, especially ultrasound based elastographic ones. The oldest and the only validated elastographic method for non-i...
متن کاملNoninvasive Assessment of Liver Disease—Measurement of Hepatic Fibrosis Using Shear Wave Elastography (SWE)
The evaluation of liver fibrosis is said to be one of the factors of the liver cancer development. The noninvasive testing is considered for abdominal echography, MRI, a blood marker in various ways. We announce the evaluation as an article by liver fibrosis using the probe for the heart before, too. This time is shear wave elastography using the echo probe for the abdomen (SWE). We used and ex...
متن کاملShear wave elastography with a new reliability indicator
Non-invasive methods for liver stiffness assessment have been introduced over recent years. Of these, two main methods for estimating liver fibrosis using ultrasound elastography have become established in clinical practice: shear wave elastography and quasi-static or strain elastography. Shear waves are waves with a motion perpendicular (lateral) to the direction of the generating force. Shear...
متن کامل