Multiple wavelength illumination in flow cytometry using a single arc lamp and a dispersing element.
نویسندگان
چکیده
The principle of a multiple wavelength illumination method for flow cytometers, based upon a combination of a helium-neon laser and an arc lamp as illumination sources is described. By using a prism, the light from the arc lamp is dispersed and the different colors are imaged at different places on the sample stream. The small angle light scattering from the helium-neon laser light is measured as a relevant parameter and serves as a trigger signal for subsequent measurements of fluorescence or scattering of light from the arc lamp. Two experimental systems are described utilizing this principle: a system where the emission is detected orthogonally with respect to the direction of the illumination beams, and an epi-illumination system. With the orthogonal set-up multiple wave-length right angle scattering measurements are possible. This is illustrated by showing that the orthogonal scattering from erythrocytes is strongly dependent on the illumination wavelength. It is further shown that the apparatus is suitable for the measurement of intracellular pH using the pH dependence of the excitation spectrum of fluorescein. The epi-illumination system allows excitation of two (or more) fluorescent dyes with different excitation spectra. In this case the emission spectra of the fluorescent dyes may overlap substantially. This is shown by simultaneous measurement of DNA and protein of Chinese hamster lung cells using mitramycin and tetramethyl rhodamin isothiocyanate (TRITC).
منابع مشابه
Observation of calcium microdomains at the uropod of living morphologically polarized human neutrophils using flash lamp-based fluorescence microscopy.
The present study outlines improved strategies for ratiometric imaging of cell calcium using a flash lamp-based excitation method and its application to neutrophil polarization. A brief (approximately 6 micros) and intense flash was used to excite the Fluo-4 and Fura Red calcium dye combination in morphologically polarized human neutrophils. These illumination conditions do not allow the dye or...
متن کاملPhotocatalytic Degradation of Bisphenol A from Aqueous Solutions using TiO2 Nanoparticles and UV Illumination
Background and Purpose: Bisphenol A (BPA) is used to make certain plastics and epoxy resins. It is a non-biodegradable compound, and poses health risks to both humans and animals. The purpose of this study was to evaluate decomposition efficiency of BPA from aqueous solutions using UV irradiation. Materials and Methods: In this study, the photodegradation of BPA in water were carrie...
متن کاملTopic Introduction Arc Lamps and Monochromators for Fluorescence Microscopy
Fluorescence microscopy requires high photon-flux densities in the specimen plane. These intensities are only achieved by lasers, arc lamps, and, most recently, light-emitting diodes (LEDs). Lasers and LEDs, however, are restricted to a limited number of wavelength regions, whereas with arc lamps it is possible to select arbitrary wavelengths and wavelength regions. Moreover, the lower cost of ...
متن کاملA large field CCD system for quantitative imaging of microarrays
We describe a charge-coupled device (CCD) imaging system for microarrays capable of acquiring quantitative, high dynamic range images of very large fields. Illumination is supplied by an arc lamp, and filters are used to define excitation and emission bands. The system is linear down to fluorochrome densities <<1 molecule/microm2. The ratios of the illumination intensity distributions for all e...
متن کاملSpeckle reduction using multiple tones of illumination.
The occurrence and smoothing of speckle are studied as a function of the line width for a highly collimated illuminating source. A general theory is presented for speckling in the image of a partially diffuse, phase type of object, which has a variable number of random scattering centers per resolution element. Then, an expression is derived for the wavelength spacing required to decouple the s...